Appliances Containing Asbestos | HSG Asbestos Surveys

Appliances Containing Asbestos: Check Your Old Heater, Boiler or Cooker Worried about an old appliance? Call us for straightforward advice and a free, no-obligation quote. We’re BOHS qualified,...

Get a Free Quote

Appliances Containing Asbestos: Check Your Old Heater, Boiler or Cooker

Worried about an old appliance? Call us for straightforward advice and a free, no-obligation quote.

We’re BOHS qualified, based in West Yorkshire and work across the North of England.

📞 07703 203930 📞 07711 855891 Get a Free Quote


BOHS P402 QualifiedBuildings Surveys & Assessment of ACMs
BOHS P405 QualifiedManagement of Asbestos in Buildings
20+ Years’ ExperienceIn the asbestos industry since the early 1990s
West Yorkshire-BasedLocal surveyors, fast turnaround

If you’re worried about appliances containing asbestos, this guide will help you check an old heater, boiler or cooker and decide what to do next. Our reference list covers more than 600 entries for electric storage radiators, electric warm air heaters and gas appliances. Some older appliances are perfectly safe to leave alone, but others need care before anyone repairs, moves or removes them.

Go straight to the appliance list

How to Check an Old Appliance

1. Leave it aloneDon’t open, dismantle or move the appliance.
2. Find the data plateNote the make, model and any serial or GC number.
3. Check the listUse the search box or open the tables further down.
4. Ask usCall if you’re unsure or the appliance is damaged.

Where Asbestos Turns Up in Older Appliances

Asbestos was used for heat insulation and fireproofing, so it’s usually found in the parts around a heat source. These are the places we’d look first:

Appliance Where asbestos may be found
Storage heaters Internal insulation, pads and small support blocks
Electric warm air heaters Insulation, including around element tails, and some gaskets
Gas boilers, fires and air heaters Gaskets, rope seals, tape, insulation, mastic and sealing washers
Ovens and cookers Door gaskets and internal linings
Hairdryers Heat shields in vintage hood dryers and some early handheld models
Ironing boards Older heat-resistant pads or covers
Simmer mats The mat itself, with a higher risk if it starts to fray

Why Age Alone Won’t Give You the Answer

The UK banned asbestos in 1999, but a pre-2000 appliance won’t automatically contain it. Plenty of older models are listed as asbestos free, while others changed part way through production. For example, some Creda storage heaters depend on whether they were made before or after June 1975, and some Vaillant boilers are marked pre 1991. That’s why the exact model, serial number and production date all matter when you’re checking for appliances containing asbestos.

How to Stay Safe Around Older Appliances

As a general rule, the risk is low if an appliance is in good condition and left alone. Damage, repairs and dismantling are what can release fibres into your home or workplace.

Do

  • Leave an undamaged appliance in place
  • Stop using it if the casing is cracked or a seal is fraying
  • Keep people away from any loose or broken material
  • Use a Gas Safe registered engineer to disconnect a gas appliance
  • Get advice before any repair, removal or heating upgrade
Don’t

  • Open the casing to look inside
  • Attempt a DIY repair on a pre-2000 appliance
  • Drill, cut, sand or break up any part of it
  • Vacuum or sweep up debris from a damaged appliance
  • Put it in a household bin or a general waste skip

Removal needs the right controls as well. The HSE’s guidance on removing a single gas or electric heater is written for trained workers, and it shows why this isn’t a DIY job.

Full Reference List of Appliances Containing Asbestos

This list is compiled from Gas Safe Register Technical Bulletin 070 (issued 7 June 2012). Search for a manufacturer, model or GC number, or open a table to browse it.

Before you rely on this list: it has been compiled from various industry sources and isn’t exhaustive. A blank Components or Comments cell doesn’t mean an appliance is safe. Marks such as * and (1) are carried over from the source list. If you have any concerns, please get specialist advice before any work, repair or removal.
Table 1: Electric Storage Radiators (Nightstore Heaters)
Manufacturer Models Containing Asbestos Asbestos Free Models
AET / Electrical Industries of Ireland IHC 8/16, 8/22, 8/27; CS 6916, 6922, 6927, 6933, 8337; CH 7016, 7021, 7027; FHC 152, 132, 172, 220, 264; FS 6803, 6804, 6805; Super 8CS, 1HC None listed
BALMFORTH SA 225; HC 260; SSHC 260; SA 300; LA 225, 200; SB 300; HC 168, 210; SSHC 168, 210 None listed
BELLING & CO LTD 758, 758A; 880 A, B, C; 890; Elite; 801, 802, 803; 811, 812, 813; 880 A, B, C, MK2; 881, 882, 883 None listed
BERRY MAGICOL See MAGICOAL None listed
BRUSH ELECTRIC CO LTD Kenton Storage Radiators; Lowstor; Cornerstor; Wallstor None listed
CHIDLOW 631, 645, 651, 661, 662, 663, 671, 672, 673, 675, 678, 691, 692, 693, 695, 696, 702*, 703-R*, 703M*, 711, 712, 713, 721, 722, 723 (1) 721, 722, 723 (1)
CONSTOR / Parkinson Cowan Heating Ltd CS, 30*, 45*, 60*, 75*, Super 3*; Contessa N-NF Range: N/NF 20*, 30*, 45*, 60*, 3000* None listed
CREDA 7001, 7002, 7110, 70001, 70041/51/52/61; Pre June 1975 production of: 70101*/70111, 70131*/70132, 70141*/70142, 72041/51/61 CH 371; CH 374; 7003; 71041/51/61; 71042/52/62; After June 1975 production of: 70101*/70111, 70131*/70132, 70141*/70142, 70156*/66/76, 70116, 72041/51/61; All TSR Heaters; All TSF* Heaters
DIMPLEX DSH 33,34,35,38,42,43,44,45,46,48,150,225,300,310; DSR 20,30,42,43,44,375 D 81,82,83; DA 81,82,83; DFB 84; DFC 85; EC 12,18,24; HB 8/200, 8/260, 8/330, 11/150, 11/225, 11/300; HB/DS 8/200, 8/260, 8/330, 11/150, 11/225, 11/300; HC 81,82,83; SC 12,18,24; XT/XTE 12,18,24
DUNLOP/WESTAYR See WESTAYR None listed
DULRAE LTD SUPASTOR None listed
ELECTROLUX None listed SH Range 1, 1A, 10B, 11B, 10C, 11C, 20A, 21A; CH Range 20, 20A; GU Range 22, 22A, 22B, 30, 30A, 30B
EMA None listed S Range
ENVIWARM None listed Hawaii *
ERSKINE/WESTAYR See WESTAYR None listed
FOLKS (Storawarm) Not Known None listed
GEC/EE / GEC of Ireland (AET) 3814, 3815, 3816; 3807/8/9; H6500/10; 1800 to 1808 inc.; 3854/5/6/7/8, 3860/1/2/3/4, 4630/1/2/5/6, 4640/1/2/5/6, 84630/5/6, 84640/1/2/5/6, 386312 (small support pad for fusible link) 3840/1/2 (Mk III)
HARPER NS 6625, 6630 None listed
HEATSTORE CFX; BXHCRX; CF3*, CF4A*, CFX3*; D-C; HCL-HCR; HCX-HWX; H724, 725, 726 (small link block support only on: BXA, HR, HRX, HXA, SDA/SCA) None listed
KENTON See Brush None listed
MAGICOAL / Berry Magicoal Ltd SR, SRC and SRO (white asbestos pad only under cut-out) Mk2 665/668; Mk3 665/668; ABC range
NEWHOME Y 1403* 1403W*; Y 1404* 1404W*; Y 1405* 1405W* None listed
PHILLIPS None listed HL
REVO WG Range; P30, 45, 60 Pennine; C30, 46, 60 Cheviot; 30U, 45U, 60U; 300, 301, 450, 600; DA*, DA1*, DA2*, DAD*; DAH 225, 003 None listed
SERVICE MK36, 36H, 39, MK40* None listed
STORAD S8, S11, S83; DL83, XL83; SR Range SRC Range
TRICITY None listed 8002, 8002A, 8003, 8003A, 8004, 8004A
TYRAD Twiggy; D 202, 250, 251, 252; TX 202, 252; C 202, 251, 252; DO 691, 693; DF 692, 694; Twilight 25, 33 None listed
UNIDARE / THERMO DARE DCFA Range; DCO Range; CUE Range; HCS 16 up to Serial No 0092528; HCS21 up to Serial No 022633; HC27 up to Serial No 030214; RR300V SA Range; WF Range; WM Range; HCS 16 after Serial No 009258; HCS21 after Serial No 022633; HC27 after Serial No 030214
WESTAYR DWA 16A, 21A, 27A (small squares between base and feet); CRA 16, 21, 26, 27; CR 16, 21, 27; CSFH 28, 36, 48; DHCA 16, 21, 27; DR 2, 3; DWB 1750, 2250, 3000; ER 200, 300, 350 None listed
Table 2: Electric Warm Air Heaters
Manufacturer Models Containing Asbestos Asbestos Free Models
ACTIVAIRE See GSW Activaire None listed
ABRDUN 6F/45; 81+/52; 6.6E38 None listed
ALLIED AE9/68 None listed
TI AURDUN LTD (previously Alexander Dunn Ltd) Serial No 66/67/68/69 (pre 1970): 4D31, 5.3D31, 5E38, 6.6E38, 6F45, 7G49, 8F45, 8H52, 9G49, 9H56, 81/52 Serial No 70/71/72/73 (from 1970): 4D31, 5.3D31, 5E38, 6.6E38, 6F45, 7G49, 8F45, 8H52, 9G49, 9H56
BALMFORTH Major 8 None listed
BELLING 9.5/64 None listed
CREDA 377 or ‘E’ range 59/60 (All except ‘E’) Types A, S, AB, SB, ABA/M, SAB, SF.6 s.6/42
ENGLISH ELECTRIC 1870/1/2/3; 1874/5/6/7 None listed
ENVIWARM B Range; S1 Range; CME (before Serial No. FBB 5873); CMD (before Serial No. EBC 5113); CMF (before Serial No. GBB 11969); CX, WF, WE, WD, 861 Superfan; CME (codes FBE); CMD (codes EBH); CMF (codes GBE)
FALKS Y Range None listed
FLETCHER 8001/8/43 None listed
GSW ACTIVAIRE A758, 19758. Asbestos compound insulation on element tails for: 6/41, 6/42, 8/50, 10/92, 11/74, 12/92, 13/90, 15/110, 15/138, 20/135 None listed
HEATOVENT 7/1 None listed
HECTRITE EL1, EL2 None listed
HUSQVARNA EL8, EL10; EL/8/2/H None listed
HVE EPD 9/60; EPC M/12; EPD L6, EPD L8, EPD L12 None listed
MARSDEN C1008 None listed
MULTITHERM C series L11F; L series 12/70/35; 556, 4681, 881, 981; D1053. Graphited asbestos gasket only on: A series, DFH412 pre 1984, 14/40, S series, E series None listed
PARKINSON COWAN 8/57 None listed
PARTRIDGE (COLSTON) PK 50, PK60 None listed
QUILTSTOR 8/45 None listed
REVO 1873, 187m; RE45, RE52, RE74, RE78 None listed
SELEX (Burco) CI006, CI008, CI0I0, CI015; SS6; D1045, D1084 None listed
UNIDARE R7/74; 8/52; 9/64 None listed
Table 3: Gas Appliances (548 models across 16 manufacturers)
Components key: CI = Insulation in electric cable | G = Gaskets | I = Insulation | MF = Mastic containing fibres | R = Rope | SW = Sealing washers | T = Tape
ACTIVAIR LTD (2 models)
Model GC Number Components
ACTIVAIR ADG 42-905-01 G
PROTOTYPE ADG (NEG) 42-905-02 G
AGCHTG.LTD (DELGLO) (40 models)
Model GC Number Components
FANFARE 20-28 SH 42-988-01 I, G, T
FANFARE 20/28 AIR HEATER 42-988-02 I, G, T
FANFARE 30/35 AIR HEATER 42-988-03 I, G, T
FANFARE 20/28R – RECESS MODEL 42-988-04 I, G, T
FANFARE 25/32 42-988-06 I, G, T
FANFARE 25/32 SH 25/32 SF 42-988-07 I, G, T
FANFARE 25/32 RD 25/32 SH RD 25/32 SFRD 42-988-08 I, G, T
FANFARE 40/60 42-988-09 I, G, T
FANFARE 25/32 LR 42-988-15 I, G, T
FANFARE 25/32 LR SH 41-988-16 I, G, T
FANFARE 25/32 LR SF 42-988-17 I, G, T
FANFARE 25/32 LR RD 42-988-18 I, G, T
FANFARE 25/32 LRSHRD 42-988-19 I, G, T
FANFARE 25/32 LRSFRD 42-988-20 I, G, T
FANFARE 25/32 LR ESTATE 42-988-21 I, G, T
FANFARE 25/32 LR SH ESTATE 42-988-22 I, G, T
FANFARE 25/32 LR SF ESTATE 42-988-23 I, G, T
FANFARE 25/32 LR RD ESTATE 42-988-24 I, G, T
FANFARE 25/32 LR SH RD ESTATE 42-988-25 I, G, T
FANFARE 25/32 LR SF RD ESTATE 42-988-26 I, G, T
FANFARE 20-28 SHW 43-988-01 I, G, T
FANFARE 20/28 W 43-988-02 I, G, T
FANFARE 30/35 W 43-988-03 I, G, T
FANFARE 25/32 W 43-988-05 I, G, T
FANFARE 25/32 SHW 25/32 SFW 43-988-06 I, G, T
FANFARE 25/32 RDW 25/32 SH RDW 25/32 SF RDW 43-988-07 I, G, T
FANFARE 40/60W 43-988-08 I, G, T
FANFARE 25/32 LRW 43-988-12 I, G, T
FANFARE 25/32 LR SHW 43-988-13 I, G, T
FANFARE 25/32 LR SFW 43-988-14 I, G, T
FANFARE 25/32 LR RDW 43-988-15 I, G, T
FANFARE 25/32 LR SH RDW 43-988-16 I, G, T
FANFARE 25/32 LR SF RDW 43-988-17 I, G, T
FANFARE 25/32 LRW ESTATE 43-988-18 I, G, T
FANFARE 25/32 LR SHW ESTATE 43-988-19 I, G, T
FANFARE 25/32 LR SFW ESTATE 43-988-20 I, G, T
FANFARE 25/32 LR RDW ESTATE 43-988-21 I, G, T
FANFARE 25/32 LR SH RDW ESTATE 43-988-22 I, G, T
FANFARE 25/32 LR SF RDW ESTATE 43-988-23 I, G, T
FANFARE 20/28R Mk3 42-988-05 I, G, T
BALMFORTH ENGINEERING LTD (6 models)
Model GC Number Components
BD 30 42-066-02 I
BD 29 42-066-08 I
BD 30 WITH ECONOMAIRE 4 42-066-12 I
BD 29 WITH ECONOMAIRE 4 42-066-13 I
BD 29WH 43-066-01 I
BD 29 WH WITH ECONOMAIRE 4 43-066-07 I
BAXI HEATING LTD (11 models)
Model GC Number Components
30 MKII MULTIGAS AIR HEATER CF 42-077-08 R, G
30 MKII MULTIGAS SD 42-077-09 R, G
30 MKI CF LH AIRHEATER 42-077-10 I
30 MKI CF RH 42-077-11 I
30 MKII CF LH 42-077-12 R, G
30 MKII CF RH 42-077-13 R, G
30 MKII SO LH 42-077-14 R, G
30 MKII SO RH 42-077-15 R, G
30 MKII MULTIGAS WITH FAN DILUTED FLUE 42-077-16 R, G
30 MKII WH COMBINED AIR & W/HEATER RH 43-077-01 R, G
30 MKII WH COMBINED AIR & W/HEATER LH 43-077-02 R, G
CARADON IDEAL (37 models)
Model GC Number Components
CONCORD COMPANION 44-392-21 G, R
MEXICO SUPER CF100 41-407-46 MF
MEXICO SUPER CF125 41-407-48 MF
MEXICO SUPER CF140 41-421-39 MF
MEXICO SUPER CF30/40 41-415-26 MF
MEXICO SUPER CF30/40 41-415-05 MF
MEXICO SUPER CF40 41-407-20 MF
MEXICO SUPER CF40/50 41-421-49 MF
MEXICO SUPER CF40/60 41-415-27 MF
MEXICO SUPER CF40/60 41-415-06 MF
MEXICO SUPER CF50/60 41-421-50 MF
MEXICO SUPER CF55 41-407-22 MF
MEXICO SUPER CF65 41-407-40 MF
MEXICO SUPER CF75 41-407-42 MF
MEXICO SUPER CF80 41-407-44 MF
MEXICO SUPER RS100 41-407-47 MF
MEXICO SUPER RS125 41-407-49 MF
MEXICO SUPER RS30/40 41-415-24 MF
MEXICO SUPER RS30/40 41-415-03 MF
MEXICO SUPER RS40 41-407-19 MF
MEXICO SUPER RS40/50 41-421-47 MF
MEXICO SUPER RS40/60 41-415-25 MF
MEXICO SUPER RS40/60 41-415-04 MF
MEXICO SUPER RS50/60 41-421-48 MF
MEXICO SUPER RS55 41-407-21 MF
MEXICO SUPER RS65 41-407-41 MF
MEXICO SUPER RS75 41-407-43 MF
MEXICO SUPER RS80 41-407-45 MF
VULCAN VERONA 55 BACK BOILER UNIT 44-348-04 MF
VULCAN VERONA 550 CAT 1N 44-348-06 MF
VULCAN VERONA 550 CAT 2TN (REDUCED) 44-348-05 MF
VULCAN VERONA 58 ROOM HEATER/BBU 44-348-03 MF
VULCAN VERONA RADIANT CONVECTOR HTR 44-348-01 R, G, T
WRS430 41-407-53 R, MF
WRS440 41-407-54 R, MF
WRS450 41-407-55 R, MF
WRS460 41-407-56 R, MF
COPPERAD LTD (2 models)
Model GC Number Components
MONARCH GWA 80 DUCTED AIR HEATER 42-176-08 I
MONARCH GWA 250 AIR HEATER C/F 42-176-14 I
CRANE LTD (46 models)
Model GC Number Components
G23/4 CF WARM AIR UNIT 42-354-07 T
G23/4 BF WARM AIR UNIT 42-354-08 T
G23/4 SD WARM AIR UNIT 42-354-09 T
25/32 WXC SD WITH ASCOT 303 WE 42-354-26 I
COMPACT 23 CF AIR HEATER 42-354-48 T
COMPACT 23 BF 42-354-49 T
COMPACT 23 SD 42-354-50 T
G23 COMPACT AIR HEATER 42-354-51 T
16/25 CF 42-354-73 G
16/25 XC CF 42-354-74 G
25/32 XC CF WITH ASCOT 303 WE 42-354-76 I
16/25 SD 42-354-78 G
16/25 XC SD 42-354-79 G
16/25 BF 42-354-80 G
16/25 XC BF 42-354-81 G
25/32 SD AIR HEATER 42-354-82 I
25/32 XC SD WITH ASCOT 303 WE 42-354-83 I
25/32 BF AIR HEATER 42-354-84 I
25/32 XC BF WITH ASCOT 303 WE 42-354-85 I
G23/30W CF WARM AIR UNIT 43-354-01 T
G23/30W BF 43-354-02 T
G23/30W SH 43-354-03 T
G23/30W XC CF 43-354-05 T
G23/30W XC SD 43-354-06 T
G23/30W XC BF 43-354-07 T
16/25 WCF AIR HEATER WITH ASCOT 303 WE 43-354-17 G
16/25 WXC CF WITH ASCOT 303 WE 43-354-18 G
25/32 WXC CF WITH ASCOT 303 WE 43-354-20 I
16/25 W SD WITH ASCOT 303 WE 43-354-21 G
16/25 WXC SD WITH ASCOT 303 WE 43-354-22 G
16/25 W BF WITH ASCOT 303 WE 43-354-23 G
16/25 WXC BF WITH ASCOT 303 WE 43-354-24 G
25/32 WXC SD WITH ASCOT 303 WE 43-354-26 I
25/32 WBF WITH ASCOT 303 WE 43-354-27 I
25/32 WXC BF WITH ASCOT 303 WE 43-354-28 I
16/25 W CF WITH MAXOL HR 30D CF 43-354-29 G
16/25 WXC CF / MAXOL HR 30D CF 43-354-30 G
16/25 W SD / MAXOL HR 30D AIR/W/HTR 43-354-31 G
16/25 WXC SD / MAXOL HR 30D SD 43-354-32 G
16/25 W BF / MAXOL HR 30D AIR/W/HTR 43-354-33 G
25/32 WCF / MAXOL HR 30D CF 43-354-35 I
25/32 WXC CF / MAXOL HR 30D CF AIR / WH 43-354-36 I
25/32 W SD / MAXOL HR 30D SD AIR / WH 43-354-37 I
25/32 WXC SD / MAXOL HR 30D SD AIR / WH 43-354-38 I
25/32 W BF / MAXOL HR 30D BF AIR W/H 43-354-39 I
25/32 WXC BF / MAXOL HR 30D BF AIR W/HTR 43-354-40 I
GENERAL STEEL WARES (7 models)
Model GC Number Components
MCCLARY SD 25/30 DOWNFLOW CF AH 42-306-29 G
MCCLARY D60/80 AH DOWNFLOW CF 42-306-40 G
MCCLARY D40/60 AIR HEATER 42-306-41 G
MCCLARY U.25.BSE AIR HEATER 42-306-44 G
MCCLARY D 40/60 WH AIR/W/HEATER 43-306-01 G
MCCLARY SD 25/30 WH / ASCOT 303 WE/1 43-306-02 G
MCCLARY SD25 42-306-36 G
GLOWWORM (150 models)
Model GC Number Components
DUCTAIR G2301 LH CF 42-618-44 G
DUCTAIR G2301 RH CF 42-618-45 G
DUCTAIR G2305 LH CF 42-618-46 G
DUCTAIR G2305 RH CF 42-618-47 G
DUCTAIR G105/23 LH TOP FLUE MODEL 42-618-48 G
DUCTAIR G105/23 TOP FLUE MODEL RH 42-618-49 G
DUCTAIR G2303 RH BF 42-618-50 G
DUCTAIR G2303 RH SD 42-618-51 G
DUCTAIR G2303 LH BF 42-618-54 G
DUCTAIR G2303 LH SD 42-618-55 G
DUCTAIR G 105/23 BF MODEL RH 42-618-58 G
DUCTAIRG 105/23 BF MODEL LH 42-618-59 G
DUCTAIR G 105/23 SE-DUCT MODEL RH 42-618-60 G
DUCTAIR G 1O5/23 SE-DUCT MODEL LH 42-618-61 G
DUCTAIR 2309/2311 BF 42-618-63 G
DUCTAIR 2309 AND 2311 SE-DUCT 42-618-64 G
DUCTAIR 3001 RH/3004 LH VT CF (WITH C28X) 43-618-06 I, G
SPACESAVER 20-30RF 41-313-86
SPACESAVER 30-40RF 41-313-87
SPACESAVER 40-50RF 41-313-88
SPACESAVER 50-60RF 41-313-89
SPACESAVER 50 B/F BOILER 41-315-27
SPACESAVER 38 B/F BOILER 41-315-31
SPACESAVER 75 B/F BOILER 41-315-32
SPACESAVER 38 CF 41-315-44
SPACESAVER 52 CF 41-315-45
SPACESAVER 75 CF 41-315-46
SPACESAVER 45-60 OPEN FLUE 41-315-63
SPACESAVER 45-60B BALANCED FLUE 41-315-64
SPACESAVER 22-30B 41-315-69
SPACESAVER 22-30 OPEN FLUE 41-315-70
105-120 CF BOILER 41-315-55
105-120B BF BOILER 41-315-56
30 SUPER ChB (OPEN FLUE) 41-315-77
30B SUPER (UWS) ChB 41-315-78
40 CF BOILER 41-315-25
40 SUPER BOILER 41-315-65
40/48 B BOILER 41-315-19
40/48 CF SB 41-315-18
40/48 SB BOILER 41-315-19
40/52 B BOILER 41-315-38
40/52 BSB BOILER 41-315-38
40/52 CF/SB AND GW 52 BOILER 41-315-37
40B SUPER (UWS) ChB 41-315-66
45-60 BOILER 41-315-49
45-60B B/F BOILER 41-315-50
52 SUPER BOILER 41-315-47
52B SUPER (UWS) BOILER 41-315-48
65-80 CAT IN CF BOILER 41-315-57
65-80 CAT 2TN CF BOILER 41-315-51
65-80B BALANCED FLUE CAT IN BOILER 41-315-58
65-80B BALANCED FLUE CAT 2TN BOILER 41-315-52
67/75 B,SB AND GW 75B 41-315-21
67/75 CF/SB AND GW 75 BOILER 41-315-20
85-100 CAT IN CF BOILER 41-315-59
85-100 CAT 2TN BOILER 41-315-53
85-100B B/F NG BOILER 41-315-60
85-100B BF 41-315-54
92/100 B SB AND GW 100B 41-315-23
92/100 CF/SB AND GW 100 BOILER 41-315-22
FUELSAVER 12CF 41-047-05
FUELSAVER 12RS 41-047-04
FUELSAVER 15CF 41-047-03
FUELSAVER 15CF 2 41-047-09
FUELSAVER 15RS 41-047-02
FUELSAVER 15RS 2 41-047-08
FUELSAVER 18RS 41-047-12
FUELSAVER 20RS 41-047-06
FUELSAVER 25-30 41-315-80
FUELSAVER 25-30B 41-315-79
FUELSAVER 30-40 41-315-82
FUELSAVER 30-40B 41-315-81
FUELSAVER 40-50 41-315-84
FUELSAVER 40-50B 41-315-83
FUELSAVER 55-60B 41-315-85
FUELSAVER 60-70B 41-315-87
FUELSAVER 9CF 41-047-11
FUELSAVER 9RS 41-047-10
SUNROD 125 BSB ALL GAS BOILER 41-314-85
SUNROD G 100 ALL GAS BOILER 41-314-78
SUNROD G 100 B 41-314-41
SUNROD G 100 B ALL GAS BOILER 41-314-80
SUNROD G 100 BASIC 41-314-39
SUNROD G 100 BSB 41-314-42
SUNROD G 100 BSB ALL GAS BOILER 41-314-81
SUNROD G 100 SB 41-314-40
SUNROD G 100 SB ALL GAS BOILER 41-314-79
SUNROD G 125 B ALL GAS BOILER 41-314-84
SUNROD G 125 B STANDARD BOILER 41-314-20
SUNROD G 125 BSB STANDARD BOILER 41-314-22
SUNROD G 125 C/F ALL GAS BOILER 41-314-82
SUNROD G 125 SB ALL GAS BOILER 41-314-83
SUNROD G 125 SB STANDARD BOILER 41-314-21
SUNROD G125 STANDARD BOILER 41-314-19
SUNROD G125B MK 2 BOILER 41-315-30
SUNROD G5 BOILER 41-314-08
SUNROD G50 ALL GAS BOILER 41-314-24
SUNROD G50 B2 BOILER 41-314-14
SUNROD G50 BF BOILER 41-314-32
SUNROD G50 BSB ALL GAS BOILER 41-314-27
SUNROD G50 HONEYWELL CONTROL 41-314-88
SUNROD G50 NON ELECT (SPERRYN 880) 41-314-86
SUNROD G50 SB ALL GAS BOILER 41-314-26
SUNROD G50 SB 41-314-10
SUNROD G50 SPERRYN CONTROL 805 41-314-87
SUNROD G50 W/- (SPERRYN G840) CF 41-315-24
SUNROD G50/2 BSB 41-314-33
SUNROD G50/2 BSB AG 41-314-31
SUNROD G50/2 HONEYWELL CONTROL 41-314-89
SUNROD G50/2 SPERRYN CONTROL 880 41-314-90
SUNROD G50/2AG 41-314-28
SUNROD G50/2SB 41-314-12
SUNROD G50/2SB AG 41-314-30
SUNROD G50/B2 AG 41-314-29
SUNROD G50B 41-314-13
SUNROD G50B ALL GAS BOILER 41-314-25
SUNROD G75 ALL GAS BOILER 41-314-74
SUNROD G75 BSB ALL GAS BOILER 41-314-77
SUNROD G75 SB ALL GAS BOILER 41-314-75
SUNROD G75 SB 41-315-09
SUNROD G75 SB 41-315-08
SUNROD G75 STD 41-315-07
SUNROD G75 STD 41-315-06
SUNROD G75B ALL GAS 41-314-76
SUNROD G75B B/F 41-315-10
SUNROD G75B BF 41-315-11
SUNROD G75B SB BF 41-315-13
SUNROD G75B SB BF 41-315-12
THERMGLOW 1 41-314-01
THERMGLOW 2 CF 41-314-48
THERMGLOW 2 CF 41-314-47
THERMGLOW 2 SB 41-314-52
THERMGLOW 2 SB 41-314-51
THERMGLOW 2B 41-314-54
THERMGLOW 2B 41-314-56
THERMGLOW 2S 41-314-49
THERMGLOW 3 ALL GAS 41-314-68
THERMGLOW 3 ALL GAS 41-314-67
THERMGLOW 3 B ALL GAS 41-314-71
THERMGLOW 3 B 41-314-62
THERMGLOW 3 41-314-57
THERMGLOW 3 BSB ALL GAS 41-314-72
THERMGLOW 3 BSB 41-314-64
THERMGLOW 3 S ALL GAS 41-314-73
THERMGLOW 3 S 41-314-65
THERMGLOW 3 SB ALL GAS 41-314-69
THERMGLOW 3 SB ALL GAS 41-314-70
THERMGLOW 3 SB 41-314-60
THERMGLOW 3 SB 41-314-59
THERMGLOW 3 41-314-58
GLYNWED LTD (2 models)
Model GC Number Components
AGA 35-40 GAS AIR HEATER 42-023-01 G, I
AGA – GAS AIR G35-40B 42-023-02 G, I
JOHNSON & STARLEY LTD (76 models)
Model GC Number Comments Components
J54-64 MAF VI 42-416-28 T
CG 50/60 HB (CG 55) AIR HEATER 42-416-47 WCM* R, I
JWD 32/45V MK2 CF AIR HEATER 42-416-60 WCM* R
J25-32 AIR HEATER 42-416-65 WCM* R, I
J25-32R AIR HEATER 42-416-66 WCM* R, I
J54/64 AIR HEATER 42-416-70 WCM* T
JWD 38/50 AIR HEATER 42-416-77 WCM* R, I
J25-32 MAF 42-416-79 WCM* R, I
J25-32R MAF 42-416-80 WCM* R, I
JWD 38/50/MAF 42-416-81 WCM* R, I
J54-64MAF 42-416-82 WCM* T
J25-32 MK2 AIR HEATER 42-416-84 WCM* R, I
J25-32R MK2 42-416-85 WCM* R, I
J25-32 MK2/MAF 42-416-88 WCM* R, I
J25-32R MK2/MAF 42-416-89 WCM* R, I
J15-22 42-417-01 R, I
J15-22R 42-417-02 R, I
J15-22 MAF 42-417-03 R, I
J15-22R1MAF 42-417-04 R, I
J25-32 MK3 AIR HEATER 42-417-11 R, I
J25-32R MK3 42-417-12 R, I
J25-32 MK3/MAF 42-417-13 R, I
J25-32R MK3/MAF 42-417-14 R, I
J25-32 MK3/MAF VI 42-417-24 R, I
J25-32R MK3/MAF VI 42-417-25 R, I
JWD 38/50/MAF VI 42-417-27 R, I
JWD 32/45V MK2 CF AIR/WH 43-416-04 T
J25-32/JAN AIR/WH 43-416-07 R, I
J25-32R/JAN AIR/WH 43-416-08 R, I
J54-64 AIR/WH 43-416-11 R, I
JWD 38/50/JAN 43-416-12 R, I
J25-32 MAF/JAN AIR/WH 43-416-13 T
J25-32R MAF/JAN AIR/WH 43-416-14 R, I
JWD 38/50/MAF/JAN 43-416-15 R, I
J54-64 MAF/JAN 43-416-16 R, I
J25-32 MK2/JAN AIRIWH 43-416-19 R, I
J25-32R MK2/JAN AIR/WH 43-416-20 R, I
J25-32 MK2/MAF/JAN AIR/WH 43-416-21 R, I
J25-32R MK2/MAF/JAN AIR/WH 43-416-22 R, I
J15-22 JAN 43-416-23 R, I
J15-22R/JAN 43-416-24 R, I
J15-22 MAF/JAN 43-416-25 R, I
J15-22R/MAF/JAN 43-416-26 R, I
J25-32 MK3/JAN 43-416-31 R, I
J25-32R MK3/JAN 43-416-32 R, I
J25-32 MK3/MAF/JAN 43-416-33 R, I
J25-32R MK3/MAF/JAN 43-416-34 R, I
J25-32 MK3/MAF V1/JAN 43-416-43 R, I
J25-32R MK3/MAF V1/JAN 43-416-44 R, I
JWD 38/50/MAF V1/JAN 43-416-46 R, I
J54-64 MAFV1/JAN 43-416-47 T
JWD 32-45 X 43-416-01 R, I
J25-32 & J25-32R REVERTED CAT 1 42-416-68 WCM* R, I
J54-64/MAF V1 42-417-28 WCM* T
J54-64 MK2/MAF 42-417-69 WCM* T
J25-32 MK3/SUPERJAN J25-32 42-417-80 WCM* R, I
J25-32 MK3/MAF/SUPERJAN 42-417-81 WCM* R, I
J25-32 MK3/MAF V1/SUPERJAN 42-417-82 WCM* R, I
J25-32R MK3/SUPERJAN 42-417-83 WCM* R, I
J25-32R MK3/MAF/SUPERJAN 42-417-84 WCM* R, I
J25-32R MK3/MAF V1/SUPERJAN 42-417-85 WCM* R, I
J25-32/JAN & 125-32 R/JAN REVERTED CAT 1 43-416-09 WCM* R, I
J25-32 Mk3/ELJ 43-416-75 R, I
J25-32 Mk3/MAF/ELJ 43-416-76 R, I
J25-32 Mk3/MAFV1/ELJ 43-416-77 R, I
J25-32R Mk3/ELJ 43-416-78 R, I
J25-32R Mk3/MAF/ELJ 43-416-79 R, I
J25-32R Mk3/MAFV1/ELJ 43-416-80 R, I
J25-32 Mk3/HIJ 43-416-90 R, I
J25/32 Mk3/MAF/HIJ 43-416-91 R, I
J25-32 Mk3/MAFV1/HIJ 43-416-92 R, I
J25-32R Mk3/HIJ 43-416-93 R, I
J25-32R Mk3/MAF/HIJ 43-416-94 R, I
J25-32R Mk3/MAFV1/HIJ 43-416-95 R, I
J54-64 Mk2/ELJ 43-417-53 T
J54-64 Mk2/MAF/ELJ 43-417-54 T
POTTERTON MYSON LTD (58 models)
Model GC Number Comments Components
WARMAIR 20/25 AIR HEATER 42-590-01 G
WARMAIR 25/30 42-590-02 G
WARMAIR28 SD 42-590-03 G
WARMAIR 40/50 AIR HEATER 42-590-05 G
WARMAIR 50/60 42-590-06 G
WARMAIR 20/25 STOREY HEIGHT WAU 42-590-07 G
WARMAIR 25/30 STOREY HEIGHT WAU 42-590-08 G
WARMAIR 20/25B, SHB, SHRB, SHBW & SHRBW 42-590-09 G
WARMAIR 25/30B SHB,SHRB,SHBW,SHRBW 42-590-09 G
WARMAIR 28SD SH MK3 AIR HEATER 42-590-13 G
WARMAIR 22/30 BASIC & SH AIR HEATERS 42-590-14 I
WARMAIR 22/30 SHW WITH ASCOT 303 WE/2 WH 42-590-14 I
WARMAIR 22/30 SHR STOREY HEIGHT AIR/WH 42-590-15 I
WARMAIR 22/30 SHRW WITH ASCOT 303 WE/2 WH 42-590-15 I
WARM-AIR 28 SD MTE AFTER 1/4/68 42-590-10 G
FLAMINGO 50BF WM 41-601-14 G, I
FLAMINGO CF20-30 41-601-33 G, I
FLAMINGO CF50 41-601-18 G, I
FLAMINGO RS 13 41-601-06 G, I
FLAMINGO RS 13 41-601-12 G, I
FLAMINGO RS20-30 41-601-23 G, I
FLAMINGO RS40 41-601-25 G, I
FLAMINGO RS50S 41-601-43 G, I
KINGFISHER 180 & 220 41-601-19 G, I
KINGFISHER 180 & 220 41-601-20 G, I
KINGFISHER 180CF 41-605-80 To Ser No GTW 16482 G, I
KINGFISHER 220CF 41-605-81 To Ser No GSV 16482 G, I
KINGFISHER CF 100 41-601-42 G, I
KINGFISHER CF 125 41-601-15 G, I
KINGFISHER CF 150 41-601-16 G, I
KINGFISHER CF40 41-601-57 To Ser No GTD 26763 G, I
KINGFISHER CF40A 41-601-60 To Ser No GTF 07186 G, I
KINGFISHER CF45 41-601-07 G, I
KINGFISHER CF50 41-601-58 To Ser No GTW 29752 G, I
KINGFISHER CF50A 41-601-61 To Ser No GSY 02260 G, I
KINGFISHER CF55 41-601-08 G, I
KINGFISHER CF60 41-601-56 To Ser No GSZ 02050 G, I
KINGFISHER CF60 41-601-38 G, I
KINGFISHER CF80 41-601-39 G, I
KINGFISHER CF90 41-601-40 G, I
KINGFISHER RS 100 41-601-59 To Ser No GTT 09197 G, I
KINGFISHER RS50 41-601-48 G, I
KINGFISHER RS50 41-601-49 G, I
KINGFISHER RS60 41-601-37 G, I
KINGFISHER RS80 41-601-41 G, I
NETAHEAT ELECTRONIC 10/16 41-601-67 To Ser No GQY 04342 G, I
NETAHEAT ELECTRONIC 16/22 41-601-66 To Ser No GQZ 04834 G, I
NETAHEAT ELECTRONIC 6/10 41-601-68 To Ser No GUA 07847 G, I
NETAHEAT MKI BF 10/16 41-601-03 To Ser No GUA 07847 G, I
NETAHEAT MKI BF 16/22 41-601-04 To Ser No GUB 18601 G, I
NETAHEAT MK2 10/16 41-601-10 To Ser No GUB 18601 G, I
NETAHEAT MK2 16/22 41-601-11 To Ser No GUC 16845 G, I
NETAHEAT Mk2e 10/16 – FIELD TRIAL 41-601-62 To Ser No GUC 16845 G, I
NETAHEAT MK2e 16/22 (FIELD TRIAL) 41-601-63 To Ser No GSC 15445 G, I
NETAHEAT MK2F 10/16 41-601-34 To Ser No GTU 06996 G, I
NETAHEAT MK2F 10/16 – PCB From Ser No PCA 41-601-34 To Ser No GTL 39870 G, I
NETAHEAT MK2F 16/22 41-601-35 To Ser No 70216 G, I
NETAHEAT MK2F 16/22 – PCB From Ser No PCB 41-601-35 To Ser No 155008 / To Ser No 20046 G, I
SPEEDAIRE LTD (LINCOLN) (13 models)
Model GC Number Components
LGCS 48 LX AIR HEATER 42-452-05 CI
LGCS 72 LX 42-452-11 CI
LGC 85 LX WARM AIR HEATER 42-452-14 CI
LGC 115 LX AIR HEATER 42-452-20 CI
LGH 115 LX 42-452-21 CI
LGL 115 LX 42-452-22 CI
LGC 130 LX 42-452-23 CI
LGH 130 LX 42-452-24 CI
LGL 130 LX 42-452-25 CI
LGC 115E 42-454-29 CI
LNC 45 43-452-17 GI
LNC 60 43-452-18 GI
LGC/S 48, 60, 72 LX 42-452-08 CI
SUTHERLAND (4 models)
Model GC Number Components
AGS 302/SH2 42-778-27 I
AGS 302/SF2 42-778-27 I
AGS 302/2 AIR HEATER 42-778-31 I
AGS 302/2 AIR AND WATER HEATER 43-778-15 I
THORN HEATING (86 models)
Model GC Number Components
HALCYON F60 C/F AIR HEATER 42-766-06 G
HALCYON FH60 AIR HEATER 42-766-08 G
HALCYON FCH 60 42-766-09 G
25/30 TN CF AIR HEATER 42-766-42 G
25/30 TN (R) CON FLUE 42-766-43 G
25/30 TN BF 42-766-44 G
25/30 TN (R) BAL FLUE 42-766-45 G
25/30 TN SD 42-766-46 G
25/30 TN (R) SE DUCT 42-766-47 G
HALCYON 22TN CF 42-766-54 G
HALCYON 22TN (R) CF 42-766-57 G
HALCYON 2 CF, BF, SD AIR HEATER 42-789-01 G
30/40A 42-789-11 G
30/40A SH 42-789-12 G
30/40A SF 42-789-13 G
THORN 30/40 AH WITH CONTROLAlRE 42-789-23 G
THORN 30/40 AH WITH CONTROLAIRE 42-789-24 G
HALCYON 22/WH BF AIR/WH 43-766-02 G
HALCYON 22/WH SD AIR/WH 43-766-03 G
HALCYON F60/WH CF AIR/AH 43-766-04 G
HALCYON F60/WH SD AIR/WH 43-766-05 G
HALCYON F60/WH BF AIR/WH 43-766-14 G
HALCYON 22 WH/TN CF/ASCOT 303 WE/1 43-766-15 G
HALCYON 22 WH/TN BF/ASCOT 303 WE/1 43-766-16 G
HALCYON 22 WH/TN SE/ASCOT 303 WE/1 43-766-17 G
HALCYON 22 WH/TN (R) CF/ASCOT 303 WE/1 43-766-18 G
HALCYON 22 WH TN (R) BF/ASCOT 303 WE/1 43-766-19 G
HALCYON 22 WH TN (R) SD/ASCOT 303 WE/1 43-766-20 G
HALCYON 25/30/WH/TN CF/ASCOT 303 WE/1 43-766-31 G
HALYCON 25/30/WH/TN/(R) CF/ASCOT 303 WE/1 43-766-32 G
HALCYON 22 WHTN / ISIS WH 43-766-38 G
HALCYON 22 WHTN(R) CF/ ISIS CIRCULATOR 43-766-39 G
HALCYON 25/30 WHITN W/ISIS WH 43-766-45 G
HALCYON 25/30 WHTN W/ISIS WH 43-766-46 G
SUGG 25/30MW WITH THORN W WH 43-766-51 G
HALCYON 2 CF, BF, SD WITH MINERVA WAE/A 43-789-01 G
30/40W 43-789-08 G
30/40 SHW 43-789-09 G
30/40 SFW 43-789-10 G
30/40WH 43-789-18 G
30/40WH AIR/WATER HEATER 43-789-19 G
HALCYON 17(R) AIR HEATER 42-766-02 G
HALCYON TYPE 35 42-766-03 G
HALCYON 35R 42-766-04 G
HALCYON F120 CONVENTIONAL 42-766-10 G
HALCYON TYPE 35 DUAL 42-766-18 G
HALCYON FH60 BF 42-766-34 G
HALCYON FH60 SD 42-766-35 G
HALCYON FCH60 BF 42-766-36 G
HALCYON FCH60 SD 42-766-37 G
HALCYON F120 BF 42-766-40 G
HALCYON F120 SD 42-766-41 G
HALCYON F60 BF 42-766-52 G
HALCYON F60 SD 42-766-53 G
HALCYON 22TN BF 42-766-55 G
HALCYON 22TN SD 42-766-56 G
HALCYON 22TN (R) BF 42-766-58 G
HALCYON 22TN (R) SD 42-766-59 G
40/50 TN (R) CF 42-766-65 G
SLIMWALL 30 AIR & AIR/WATER HTR SERIES 42-766-67 G
SLIMWALL 30 TN (R) CF 42-766-68 G
SLIMWALL 30 TN RD CF WITH RISING DUCT 42-766-74 G
SLIMWALL 30 TN RD CF R.C. RISING DUCT 42-766-75 G
SLIMWALL 30TN SD WARM AIR HEATER 42-766-76 G
SLIMWALL 30 TN SD(R) 42-766-77 G
HALCYON 40/60 AIR HEATER 42-766-82 G
HALCYON 60/80 AIR HEATER 42-766-83 G
SUGG 25/30M AIR HEATER 42-766-88 G
30/40A AIR HEATER FITTED CONTROLAIRE 42-789-18 G
HALCYON TYPE 22 WH CONV 43-766-01 G
HALCYON F120 WH COMBINED AIR/WH 43-766-06 G
HALCYON F120 WH BALANCED FLUE 43-766-07 G
HALCYON F120 WH SEDUCT 43-766-08 G
HALCYON 17WH(R) AIR/WATER HEATER 43-766-10 G
HALCYON TYPE 22 WH CONVENTIONAL (R) 43-766-11 G
HALCYON TYPE 22 WH BALANCED FLUE (R) 43-766-12 G
HALCYON TYPE 22 WH SEDUCT 43-766-13 G
SLIMWALL 30 WH TN CF / ASCOT WE/1 43-766-27 G
SLIMWALL 30 WH TN WITH ASCOT 303WE/1 43-766-28 G
SLIMWALL 30 WH TN RD WITH ASCOT 303WE/1 43-766-29 G
SLIMWALL 30 WH TN RD(R) WITH ASCOT 303 WE/1 43-766-30 G
HALCYON 40/60 WH AIRIW/H (MADE BY GSW) 43-766-40 G
SUGG 25/30M WITH ISIS CIRCULATOR WAE/C 43-766-44 G
SUGG 25/30M WITH MINERVA WAE/C 43-766-47 G
SUGG 25/30M WITH MAXOL TH 30/D 43-766-50 G
30/40W AIR/WATER HEATER WITH CONTROLAIRE 43-789-15 G
VAILLANT (8 models)
Model GC Number Comments Components
COMBICOMPACT VCW 242E 47-044-13 Pre 1991
COMBICOMPACT VCW 282E 47-044-18 Pre 1991
T3W VCW SINE 18 47-044-01 Pre 1991
T3W VCW SINE 20/1 47-044-03 Pre 1991
T3W VCW SINE 25/1 47-044-05 Pre 1991
COMBICOMPACT VCW 221 47-044-14 SW
COMBICOMPACT VCW 240 47-044-15 SW
COMBICOMPACT VCW 280 47-044-16 SW

Source: Gas Safe Register Technical Bulletin 070, issued 7 June 2012, compiled in association with HSE Information Document OC No. 265/49 (Rev 1). Provided for general reference only.

Can’t find your appliance, or not sure what the list means?

Tell us the make and model and we’ll talk you through your options. A photo of the data plate helps, as long as you can take it without opening or moving the appliance.

📞 07703 203930 📞 07711 855891

How HSG Surveys Can Help

We work with homeowners, landlords, letting agents, businesses and contractors who’ve found an old appliance and need a clear answer before they go any further.

Asbestos Management Surveys

If you’re responsible for a workplace or the common parts of a multi-occupied building, a management survey shows where asbestos could be disturbed during normal use and routine maintenance. It can include older appliances containing asbestos, and it gives you a written record to work from. Read our full guide to how these surveys work.

Asbestos Refurbishment & Demolition Surveys

Replacing a heating system or refitting a kitchen in a pre-2000 building can disturb far more than the appliance itself. A refurbishment and demolition survey checks the areas being worked on, so appliances containing asbestos and hidden materials nearby can be dealt with before contractors start. See our detailed breakdown of this survey type.

Asbestos Sampling & Testing

Sometimes you only need an answer about one material. Where it can be reached safely, we can take a bulk sample from suspected appliances containing asbestos and send it to a UKAS-accredited laboratory, with results typically back within a few working days. Find out more about sampling and testing.

Areas We Cover

We’re based in West Yorkshire and carry out inspections, sampling and surveys across the North of England. Take a look at our West Yorkshire coverage page, or call us and we’ll confirm coverage for your area.

Appliances Containing Asbestos – Frequently Asked Questions

Does my old appliance contain asbestos?

You can’t tell by looking at it. Note the make, model and any serial or GC number from the data plate, then check them against our reference list. If you can’t find a clear match, leave the appliance alone and call us for advice.

What if my appliance isn’t on the list?

That doesn’t prove it’s asbestos free. The list isn’t exhaustive, so treat an older appliance with caution until you have a clear answer, especially if it’s damaged or due to be moved.

If my model is listed as asbestos free, is it definitely safe to work on?

It’s a good sign, but check the exact model, serial number and production date, because some entries depend on all three. Parts may also have been replaced over the years, so take specialist advice if there’s any doubt.

Do I have to remove a heater that contains asbestos?

Not usually. A heater in good condition can often stay where it is, as long as it isn’t damaged or disturbed. Removal becomes important when it’s deteriorating or when refurbishment work will affect it, and that job shouldn’t be done as DIY.

Can you test appliances containing asbestos?

Yes, where the material can be reached safely. We can inspect the appliance, take a sample if it’s suitable and send it to a UKAS-accredited laboratory for analysis. Please don’t open the casing or take your own sample first.

How do I get rid of appliances containing asbestos?

Don’t put them in a household bin or a general waste skip. Appliances containing asbestos need to be removed and disposed of as asbestos waste, so call us before you disconnect or move one. We’ll explain the safest route for your property.

Should landlords check for appliances containing asbestos?

Yes, particularly before maintenance, a heating upgrade or a change of tenant. Knowing whether a property has appliances containing asbestos helps you warn contractors and plan work safely. The duty to manage asbestos also applies to the common parts of multi-occupied buildings.

Not sure if your appliance is on the list?

Free, no-obligation quotes, usually back to you the same day.

📞 07703 203930 📞 07711 855891 Get a Free Quote

Request a call back