Appliances Containing Asbestos: Check Your Old Heater, Boiler or Cooker
Worried about an old appliance? Call us for straightforward advice and a free, no-obligation quote.
We’re BOHS qualified, based in West Yorkshire and work across the North of England.
📞 07703 203930 📞 07711 855891 Get a Free Quote
BOHS P402 QualifiedBuildings Surveys & Assessment of ACMs
BOHS P405 QualifiedManagement of Asbestos in Buildings
20+ Years’ ExperienceIn the asbestos industry since the early 1990s
West Yorkshire-BasedLocal surveyors, fast turnaround
If you’re worried about appliances containing asbestos, this guide will help you check an old heater, boiler or cooker and decide what to do next. Our reference list covers more than 600 entries for electric storage radiators, electric warm air heaters and gas appliances. Some older appliances are perfectly safe to leave alone, but others need care before anyone repairs, moves or removes them.
Go straight to the appliance list
How to Check an Old Appliance
1. Leave it aloneDon’t open, dismantle or move the appliance.
2. Find the data plateNote the make, model and any serial or GC number.
3. Check the listUse the search box or open the tables further down.
4. Ask usCall if you’re unsure or the appliance is damaged.
Where Asbestos Turns Up in Older Appliances
Asbestos was used for heat insulation and fireproofing, so it’s usually found in the parts around a heat source. These are the places we’d look first:
| Appliance |
Where asbestos may be found |
| Storage heaters |
Internal insulation, pads and small support blocks |
| Electric warm air heaters |
Insulation, including around element tails, and some gaskets |
| Gas boilers, fires and air heaters |
Gaskets, rope seals, tape, insulation, mastic and sealing washers |
| Ovens and cookers |
Door gaskets and internal linings |
| Hairdryers |
Heat shields in vintage hood dryers and some early handheld models |
| Ironing boards |
Older heat-resistant pads or covers |
| Simmer mats |
The mat itself, with a higher risk if it starts to fray |
Why Age Alone Won’t Give You the Answer
The UK banned asbestos in 1999, but a pre-2000 appliance won’t automatically contain it. Plenty of older models are listed as asbestos free, while others changed part way through production. For example, some Creda storage heaters depend on whether they were made before or after June 1975, and some Vaillant boilers are marked pre 1991. That’s why the exact model, serial number and production date all matter when you’re checking for appliances containing asbestos.
How to Stay Safe Around Older Appliances
As a general rule, the risk is low if an appliance is in good condition and left alone. Damage, repairs and dismantling are what can release fibres into your home or workplace.
Do
- Leave an undamaged appliance in place
- Stop using it if the casing is cracked or a seal is fraying
- Keep people away from any loose or broken material
- Use a Gas Safe registered engineer to disconnect a gas appliance
- Get advice before any repair, removal or heating upgrade
Don’t
- Open the casing to look inside
- Attempt a DIY repair on a pre-2000 appliance
- Drill, cut, sand or break up any part of it
- Vacuum or sweep up debris from a damaged appliance
- Put it in a household bin or a general waste skip
Removal needs the right controls as well. The HSE’s guidance on removing a single gas or electric heater is written for trained workers, and it shows why this isn’t a DIY job.
Full Reference List of Appliances Containing Asbestos
This list is compiled from Gas Safe Register Technical Bulletin 070 (issued 7 June 2012). Search for a manufacturer, model or GC number, or open a table to browse it.
Before you rely on this list: it has been compiled from various industry sources and isn’t exhaustive. A blank Components or Comments cell doesn’t mean an appliance is safe. Marks such as * and (1) are carried over from the source list. If you have any concerns, please get specialist advice before any work, repair or removal.
Table 1: Electric Storage Radiators (Nightstore Heaters)
| Manufacturer |
Models Containing Asbestos |
Asbestos Free Models |
| AET / Electrical Industries of Ireland |
IHC 8/16, 8/22, 8/27; CS 6916, 6922, 6927, 6933, 8337; CH 7016, 7021, 7027; FHC 152, 132, 172, 220, 264; FS 6803, 6804, 6805; Super 8CS, 1HC |
None listed |
| BALMFORTH |
SA 225; HC 260; SSHC 260; SA 300; LA 225, 200; SB 300; HC 168, 210; SSHC 168, 210 |
None listed |
| BELLING & CO LTD |
758, 758A; 880 A, B, C; 890; Elite; 801, 802, 803; 811, 812, 813; 880 A, B, C, MK2; 881, 882, 883 |
None listed |
| BERRY MAGICOL |
See MAGICOAL |
None listed |
| BRUSH ELECTRIC CO LTD |
Kenton Storage Radiators; Lowstor; Cornerstor; Wallstor |
None listed |
| CHIDLOW |
631, 645, 651, 661, 662, 663, 671, 672, 673, 675, 678, 691, 692, 693, 695, 696, 702*, 703-R*, 703M*, 711, 712, 713, 721, 722, 723 (1) |
721, 722, 723 (1) |
| CONSTOR / Parkinson Cowan Heating Ltd |
CS, 30*, 45*, 60*, 75*, Super 3*; Contessa N-NF Range: N/NF 20*, 30*, 45*, 60*, 3000* |
None listed |
| CREDA |
7001, 7002, 7110, 70001, 70041/51/52/61; Pre June 1975 production of: 70101*/70111, 70131*/70132, 70141*/70142, 72041/51/61 |
CH 371; CH 374; 7003; 71041/51/61; 71042/52/62; After June 1975 production of: 70101*/70111, 70131*/70132, 70141*/70142, 70156*/66/76, 70116, 72041/51/61; All TSR Heaters; All TSF* Heaters |
| DIMPLEX |
DSH 33,34,35,38,42,43,44,45,46,48,150,225,300,310; DSR 20,30,42,43,44,375 |
D 81,82,83; DA 81,82,83; DFB 84; DFC 85; EC 12,18,24; HB 8/200, 8/260, 8/330, 11/150, 11/225, 11/300; HB/DS 8/200, 8/260, 8/330, 11/150, 11/225, 11/300; HC 81,82,83; SC 12,18,24; XT/XTE 12,18,24 |
| DUNLOP/WESTAYR |
See WESTAYR |
None listed |
| DULRAE LTD |
SUPASTOR |
None listed |
| ELECTROLUX |
None listed |
SH Range 1, 1A, 10B, 11B, 10C, 11C, 20A, 21A; CH Range 20, 20A; GU Range 22, 22A, 22B, 30, 30A, 30B |
| EMA |
None listed |
S Range |
| ENVIWARM |
None listed |
Hawaii * |
| ERSKINE/WESTAYR |
See WESTAYR |
None listed |
| FOLKS (Storawarm) |
Not Known |
None listed |
| GEC/EE / GEC of Ireland (AET) |
3814, 3815, 3816; 3807/8/9; H6500/10; 1800 to 1808 inc.; 3854/5/6/7/8, 3860/1/2/3/4, 4630/1/2/5/6, 4640/1/2/5/6, 84630/5/6, 84640/1/2/5/6, 386312 (small support pad for fusible link) |
3840/1/2 (Mk III) |
| HARPER |
NS 6625, 6630 |
None listed |
| HEATSTORE |
CFX; BXHCRX; CF3*, CF4A*, CFX3*; D-C; HCL-HCR; HCX-HWX; H724, 725, 726 (small link block support only on: BXA, HR, HRX, HXA, SDA/SCA) |
None listed |
| KENTON |
See Brush |
None listed |
| MAGICOAL / Berry Magicoal Ltd |
SR, SRC and SRO (white asbestos pad only under cut-out) |
Mk2 665/668; Mk3 665/668; ABC range |
| NEWHOME |
Y 1403* 1403W*; Y 1404* 1404W*; Y 1405* 1405W* |
None listed |
| PHILLIPS |
None listed |
HL |
| REVO |
WG Range; P30, 45, 60 Pennine; C30, 46, 60 Cheviot; 30U, 45U, 60U; 300, 301, 450, 600; DA*, DA1*, DA2*, DAD*; DAH 225, 003 |
None listed |
| SERVICE |
MK36, 36H, 39, MK40* |
None listed |
| STORAD |
S8, S11, S83; DL83, XL83; SR Range |
SRC Range |
| TRICITY |
None listed |
8002, 8002A, 8003, 8003A, 8004, 8004A |
| TYRAD |
Twiggy; D 202, 250, 251, 252; TX 202, 252; C 202, 251, 252; DO 691, 693; DF 692, 694; Twilight 25, 33 |
None listed |
| UNIDARE / THERMO DARE |
DCFA Range; DCO Range; CUE Range; HCS 16 up to Serial No 0092528; HCS21 up to Serial No 022633; HC27 up to Serial No 030214; RR300V |
SA Range; WF Range; WM Range; HCS 16 after Serial No 009258; HCS21 after Serial No 022633; HC27 after Serial No 030214 |
| WESTAYR |
DWA 16A, 21A, 27A (small squares between base and feet); CRA 16, 21, 26, 27; CR 16, 21, 27; CSFH 28, 36, 48; DHCA 16, 21, 27; DR 2, 3; DWB 1750, 2250, 3000; ER 200, 300, 350 |
None listed |
Table 2: Electric Warm Air Heaters
| Manufacturer |
Models Containing Asbestos |
Asbestos Free Models |
| ACTIVAIRE |
See GSW Activaire |
None listed |
| ABRDUN |
6F/45; 81+/52; 6.6E38 |
None listed |
| ALLIED |
AE9/68 |
None listed |
| TI AURDUN LTD (previously Alexander Dunn Ltd) |
Serial No 66/67/68/69 (pre 1970): 4D31, 5.3D31, 5E38, 6.6E38, 6F45, 7G49, 8F45, 8H52, 9G49, 9H56, 81/52 |
Serial No 70/71/72/73 (from 1970): 4D31, 5.3D31, 5E38, 6.6E38, 6F45, 7G49, 8F45, 8H52, 9G49, 9H56 |
| BALMFORTH |
Major 8 |
None listed |
| BELLING |
9.5/64 |
None listed |
| CREDA |
377 or ‘E’ range 59/60 |
(All except ‘E’) Types A, S, AB, SB, ABA/M, SAB, SF.6 s.6/42 |
| ENGLISH ELECTRIC |
1870/1/2/3; 1874/5/6/7 |
None listed |
| ENVIWARM |
B Range; S1 Range; CME (before Serial No. FBB 5873); CMD (before Serial No. EBC 5113); CMF (before Serial No. GBB 11969); CX, WF, WE, WD, 861 |
Superfan; CME (codes FBE); CMD (codes EBH); CMF (codes GBE) |
| FALKS |
Y Range |
None listed |
| FLETCHER |
8001/8/43 |
None listed |
| GSW ACTIVAIRE |
A758, 19758. Asbestos compound insulation on element tails for: 6/41, 6/42, 8/50, 10/92, 11/74, 12/92, 13/90, 15/110, 15/138, 20/135 |
None listed |
| HEATOVENT |
7/1 |
None listed |
| HECTRITE |
EL1, EL2 |
None listed |
| HUSQVARNA |
EL8, EL10; EL/8/2/H |
None listed |
| HVE |
EPD 9/60; EPC M/12; EPD L6, EPD L8, EPD L12 |
None listed |
| MARSDEN |
C1008 |
None listed |
| MULTITHERM |
C series L11F; L series 12/70/35; 556, 4681, 881, 981; D1053. Graphited asbestos gasket only on: A series, DFH412 pre 1984, 14/40, S series, E series |
None listed |
| PARKINSON COWAN |
8/57 |
None listed |
| PARTRIDGE (COLSTON) |
PK 50, PK60 |
None listed |
| QUILTSTOR |
8/45 |
None listed |
| REVO |
1873, 187m; RE45, RE52, RE74, RE78 |
None listed |
| SELEX (Burco) |
CI006, CI008, CI0I0, CI015; SS6; D1045, D1084 |
None listed |
| UNIDARE |
R7/74; 8/52; 9/64 |
None listed |
Table 3: Gas Appliances (548 models across 16 manufacturers)
Components key: CI = Insulation in electric cable | G = Gaskets | I = Insulation | MF = Mastic containing fibres | R = Rope | SW = Sealing washers | T = Tape
ACTIVAIR LTD (2 models)
| Model |
GC Number |
Components |
| ACTIVAIR ADG |
42-905-01 |
G |
| PROTOTYPE ADG (NEG) |
42-905-02 |
G |
AGCHTG.LTD (DELGLO) (40 models)
| Model |
GC Number |
Components |
| FANFARE 20-28 SH |
42-988-01 |
I, G, T |
| FANFARE 20/28 AIR HEATER |
42-988-02 |
I, G, T |
| FANFARE 30/35 AIR HEATER |
42-988-03 |
I, G, T |
| FANFARE 20/28R – RECESS MODEL |
42-988-04 |
I, G, T |
| FANFARE 25/32 |
42-988-06 |
I, G, T |
| FANFARE 25/32 SH 25/32 SF |
42-988-07 |
I, G, T |
| FANFARE 25/32 RD 25/32 SH RD 25/32 SFRD |
42-988-08 |
I, G, T |
| FANFARE 40/60 |
42-988-09 |
I, G, T |
| FANFARE 25/32 LR |
42-988-15 |
I, G, T |
| FANFARE 25/32 LR SH |
41-988-16 |
I, G, T |
| FANFARE 25/32 LR SF |
42-988-17 |
I, G, T |
| FANFARE 25/32 LR RD |
42-988-18 |
I, G, T |
| FANFARE 25/32 LRSHRD |
42-988-19 |
I, G, T |
| FANFARE 25/32 LRSFRD |
42-988-20 |
I, G, T |
| FANFARE 25/32 LR ESTATE |
42-988-21 |
I, G, T |
| FANFARE 25/32 LR SH ESTATE |
42-988-22 |
I, G, T |
| FANFARE 25/32 LR SF ESTATE |
42-988-23 |
I, G, T |
| FANFARE 25/32 LR RD ESTATE |
42-988-24 |
I, G, T |
| FANFARE 25/32 LR SH RD ESTATE |
42-988-25 |
I, G, T |
| FANFARE 25/32 LR SF RD ESTATE |
42-988-26 |
I, G, T |
| FANFARE 20-28 SHW |
43-988-01 |
I, G, T |
| FANFARE 20/28 W |
43-988-02 |
I, G, T |
| FANFARE 30/35 W |
43-988-03 |
I, G, T |
| FANFARE 25/32 W |
43-988-05 |
I, G, T |
| FANFARE 25/32 SHW 25/32 SFW |
43-988-06 |
I, G, T |
| FANFARE 25/32 RDW 25/32 SH RDW 25/32 SF RDW |
43-988-07 |
I, G, T |
| FANFARE 40/60W |
43-988-08 |
I, G, T |
| FANFARE 25/32 LRW |
43-988-12 |
I, G, T |
| FANFARE 25/32 LR SHW |
43-988-13 |
I, G, T |
| FANFARE 25/32 LR SFW |
43-988-14 |
I, G, T |
| FANFARE 25/32 LR RDW |
43-988-15 |
I, G, T |
| FANFARE 25/32 LR SH RDW |
43-988-16 |
I, G, T |
| FANFARE 25/32 LR SF RDW |
43-988-17 |
I, G, T |
| FANFARE 25/32 LRW ESTATE |
43-988-18 |
I, G, T |
| FANFARE 25/32 LR SHW ESTATE |
43-988-19 |
I, G, T |
| FANFARE 25/32 LR SFW ESTATE |
43-988-20 |
I, G, T |
| FANFARE 25/32 LR RDW ESTATE |
43-988-21 |
I, G, T |
| FANFARE 25/32 LR SH RDW ESTATE |
43-988-22 |
I, G, T |
| FANFARE 25/32 LR SF RDW ESTATE |
43-988-23 |
I, G, T |
| FANFARE 20/28R Mk3 |
42-988-05 |
I, G, T |
BALMFORTH ENGINEERING LTD (6 models)
| Model |
GC Number |
Components |
| BD 30 |
42-066-02 |
I |
| BD 29 |
42-066-08 |
I |
| BD 30 WITH ECONOMAIRE 4 |
42-066-12 |
I |
| BD 29 WITH ECONOMAIRE 4 |
42-066-13 |
I |
| BD 29WH |
43-066-01 |
I |
| BD 29 WH WITH ECONOMAIRE 4 |
43-066-07 |
I |
BAXI HEATING LTD (11 models)
| Model |
GC Number |
Components |
| 30 MKII MULTIGAS AIR HEATER CF |
42-077-08 |
R, G |
| 30 MKII MULTIGAS SD |
42-077-09 |
R, G |
| 30 MKI CF LH AIRHEATER |
42-077-10 |
I |
| 30 MKI CF RH |
42-077-11 |
I |
| 30 MKII CF LH |
42-077-12 |
R, G |
| 30 MKII CF RH |
42-077-13 |
R, G |
| 30 MKII SO LH |
42-077-14 |
R, G |
| 30 MKII SO RH |
42-077-15 |
R, G |
| 30 MKII MULTIGAS WITH FAN DILUTED FLUE |
42-077-16 |
R, G |
| 30 MKII WH COMBINED AIR & W/HEATER RH |
43-077-01 |
R, G |
| 30 MKII WH COMBINED AIR & W/HEATER LH |
43-077-02 |
R, G |
CARADON IDEAL (37 models)
| Model |
GC Number |
Components |
| CONCORD COMPANION |
44-392-21 |
G, R |
| MEXICO SUPER CF100 |
41-407-46 |
MF |
| MEXICO SUPER CF125 |
41-407-48 |
MF |
| MEXICO SUPER CF140 |
41-421-39 |
MF |
| MEXICO SUPER CF30/40 |
41-415-26 |
MF |
| MEXICO SUPER CF30/40 |
41-415-05 |
MF |
| MEXICO SUPER CF40 |
41-407-20 |
MF |
| MEXICO SUPER CF40/50 |
41-421-49 |
MF |
| MEXICO SUPER CF40/60 |
41-415-27 |
MF |
| MEXICO SUPER CF40/60 |
41-415-06 |
MF |
| MEXICO SUPER CF50/60 |
41-421-50 |
MF |
| MEXICO SUPER CF55 |
41-407-22 |
MF |
| MEXICO SUPER CF65 |
41-407-40 |
MF |
| MEXICO SUPER CF75 |
41-407-42 |
MF |
| MEXICO SUPER CF80 |
41-407-44 |
MF |
| MEXICO SUPER RS100 |
41-407-47 |
MF |
| MEXICO SUPER RS125 |
41-407-49 |
MF |
| MEXICO SUPER RS30/40 |
41-415-24 |
MF |
| MEXICO SUPER RS30/40 |
41-415-03 |
MF |
| MEXICO SUPER RS40 |
41-407-19 |
MF |
| MEXICO SUPER RS40/50 |
41-421-47 |
MF |
| MEXICO SUPER RS40/60 |
41-415-25 |
MF |
| MEXICO SUPER RS40/60 |
41-415-04 |
MF |
| MEXICO SUPER RS50/60 |
41-421-48 |
MF |
| MEXICO SUPER RS55 |
41-407-21 |
MF |
| MEXICO SUPER RS65 |
41-407-41 |
MF |
| MEXICO SUPER RS75 |
41-407-43 |
MF |
| MEXICO SUPER RS80 |
41-407-45 |
MF |
| VULCAN VERONA 55 BACK BOILER UNIT |
44-348-04 |
MF |
| VULCAN VERONA 550 CAT 1N |
44-348-06 |
MF |
| VULCAN VERONA 550 CAT 2TN (REDUCED) |
44-348-05 |
MF |
| VULCAN VERONA 58 ROOM HEATER/BBU |
44-348-03 |
MF |
| VULCAN VERONA RADIANT CONVECTOR HTR |
44-348-01 |
R, G, T |
| WRS430 |
41-407-53 |
R, MF |
| WRS440 |
41-407-54 |
R, MF |
| WRS450 |
41-407-55 |
R, MF |
| WRS460 |
41-407-56 |
R, MF |
COPPERAD LTD (2 models)
| Model |
GC Number |
Components |
| MONARCH GWA 80 DUCTED AIR HEATER |
42-176-08 |
I |
| MONARCH GWA 250 AIR HEATER C/F |
42-176-14 |
I |
CRANE LTD (46 models)
| Model |
GC Number |
Components |
| G23/4 CF WARM AIR UNIT |
42-354-07 |
T |
| G23/4 BF WARM AIR UNIT |
42-354-08 |
T |
| G23/4 SD WARM AIR UNIT |
42-354-09 |
T |
| 25/32 WXC SD WITH ASCOT 303 WE |
42-354-26 |
I |
| COMPACT 23 CF AIR HEATER |
42-354-48 |
T |
| COMPACT 23 BF |
42-354-49 |
T |
| COMPACT 23 SD |
42-354-50 |
T |
| G23 COMPACT AIR HEATER |
42-354-51 |
T |
| 16/25 CF |
42-354-73 |
G |
| 16/25 XC CF |
42-354-74 |
G |
| 25/32 XC CF WITH ASCOT 303 WE |
42-354-76 |
I |
| 16/25 SD |
42-354-78 |
G |
| 16/25 XC SD |
42-354-79 |
G |
| 16/25 BF |
42-354-80 |
G |
| 16/25 XC BF |
42-354-81 |
G |
| 25/32 SD AIR HEATER |
42-354-82 |
I |
| 25/32 XC SD WITH ASCOT 303 WE |
42-354-83 |
I |
| 25/32 BF AIR HEATER |
42-354-84 |
I |
| 25/32 XC BF WITH ASCOT 303 WE |
42-354-85 |
I |
| G23/30W CF WARM AIR UNIT |
43-354-01 |
T |
| G23/30W BF |
43-354-02 |
T |
| G23/30W SH |
43-354-03 |
T |
| G23/30W XC CF |
43-354-05 |
T |
| G23/30W XC SD |
43-354-06 |
T |
| G23/30W XC BF |
43-354-07 |
T |
| 16/25 WCF AIR HEATER WITH ASCOT 303 WE |
43-354-17 |
G |
| 16/25 WXC CF WITH ASCOT 303 WE |
43-354-18 |
G |
| 25/32 WXC CF WITH ASCOT 303 WE |
43-354-20 |
I |
| 16/25 W SD WITH ASCOT 303 WE |
43-354-21 |
G |
| 16/25 WXC SD WITH ASCOT 303 WE |
43-354-22 |
G |
| 16/25 W BF WITH ASCOT 303 WE |
43-354-23 |
G |
| 16/25 WXC BF WITH ASCOT 303 WE |
43-354-24 |
G |
| 25/32 WXC SD WITH ASCOT 303 WE |
43-354-26 |
I |
| 25/32 WBF WITH ASCOT 303 WE |
43-354-27 |
I |
| 25/32 WXC BF WITH ASCOT 303 WE |
43-354-28 |
I |
| 16/25 W CF WITH MAXOL HR 30D CF |
43-354-29 |
G |
| 16/25 WXC CF / MAXOL HR 30D CF |
43-354-30 |
G |
| 16/25 W SD / MAXOL HR 30D AIR/W/HTR |
43-354-31 |
G |
| 16/25 WXC SD / MAXOL HR 30D SD |
43-354-32 |
G |
| 16/25 W BF / MAXOL HR 30D AIR/W/HTR |
43-354-33 |
G |
| 25/32 WCF / MAXOL HR 30D CF |
43-354-35 |
I |
| 25/32 WXC CF / MAXOL HR 30D CF AIR / WH |
43-354-36 |
I |
| 25/32 W SD / MAXOL HR 30D SD AIR / WH |
43-354-37 |
I |
| 25/32 WXC SD / MAXOL HR 30D SD AIR / WH |
43-354-38 |
I |
| 25/32 W BF / MAXOL HR 30D BF AIR W/H |
43-354-39 |
I |
| 25/32 WXC BF / MAXOL HR 30D BF AIR W/HTR |
43-354-40 |
I |
GENERAL STEEL WARES (7 models)
| Model |
GC Number |
Components |
| MCCLARY SD 25/30 DOWNFLOW CF AH |
42-306-29 |
G |
| MCCLARY D60/80 AH DOWNFLOW CF |
42-306-40 |
G |
| MCCLARY D40/60 AIR HEATER |
42-306-41 |
G |
| MCCLARY U.25.BSE AIR HEATER |
42-306-44 |
G |
| MCCLARY D 40/60 WH AIR/W/HEATER |
43-306-01 |
G |
| MCCLARY SD 25/30 WH / ASCOT 303 WE/1 |
43-306-02 |
G |
| MCCLARY SD25 |
42-306-36 |
G |
GLOWWORM (150 models)
| Model |
GC Number |
Components |
| DUCTAIR G2301 LH CF |
42-618-44 |
G |
| DUCTAIR G2301 RH CF |
42-618-45 |
G |
| DUCTAIR G2305 LH CF |
42-618-46 |
G |
| DUCTAIR G2305 RH CF |
42-618-47 |
G |
| DUCTAIR G105/23 LH TOP FLUE MODEL |
42-618-48 |
G |
| DUCTAIR G105/23 TOP FLUE MODEL RH |
42-618-49 |
G |
| DUCTAIR G2303 RH BF |
42-618-50 |
G |
| DUCTAIR G2303 RH SD |
42-618-51 |
G |
| DUCTAIR G2303 LH BF |
42-618-54 |
G |
| DUCTAIR G2303 LH SD |
42-618-55 |
G |
| DUCTAIR G 105/23 BF MODEL RH |
42-618-58 |
G |
| DUCTAIRG 105/23 BF MODEL LH |
42-618-59 |
G |
| DUCTAIR G 105/23 SE-DUCT MODEL RH |
42-618-60 |
G |
| DUCTAIR G 1O5/23 SE-DUCT MODEL LH |
42-618-61 |
G |
| DUCTAIR 2309/2311 BF |
42-618-63 |
G |
| DUCTAIR 2309 AND 2311 SE-DUCT |
42-618-64 |
G |
| DUCTAIR 3001 RH/3004 LH VT CF (WITH C28X) |
43-618-06 |
I, G |
| SPACESAVER 20-30RF |
41-313-86 |
|
| SPACESAVER 30-40RF |
41-313-87 |
|
| SPACESAVER 40-50RF |
41-313-88 |
|
| SPACESAVER 50-60RF |
41-313-89 |
|
| SPACESAVER 50 B/F BOILER |
41-315-27 |
|
| SPACESAVER 38 B/F BOILER |
41-315-31 |
|
| SPACESAVER 75 B/F BOILER |
41-315-32 |
|
| SPACESAVER 38 CF |
41-315-44 |
|
| SPACESAVER 52 CF |
41-315-45 |
|
| SPACESAVER 75 CF |
41-315-46 |
|
| SPACESAVER 45-60 OPEN FLUE |
41-315-63 |
|
| SPACESAVER 45-60B BALANCED FLUE |
41-315-64 |
|
| SPACESAVER 22-30B |
41-315-69 |
|
| SPACESAVER 22-30 OPEN FLUE |
41-315-70 |
|
| 105-120 CF BOILER |
41-315-55 |
|
| 105-120B BF BOILER |
41-315-56 |
|
| 30 SUPER ChB (OPEN FLUE) |
41-315-77 |
|
| 30B SUPER (UWS) ChB |
41-315-78 |
|
| 40 CF BOILER |
41-315-25 |
|
| 40 SUPER BOILER |
41-315-65 |
|
| 40/48 B BOILER |
41-315-19 |
|
| 40/48 CF SB |
41-315-18 |
|
| 40/48 SB BOILER |
41-315-19 |
|
| 40/52 B BOILER |
41-315-38 |
|
| 40/52 BSB BOILER |
41-315-38 |
|
| 40/52 CF/SB AND GW 52 BOILER |
41-315-37 |
|
| 40B SUPER (UWS) ChB |
41-315-66 |
|
| 45-60 BOILER |
41-315-49 |
|
| 45-60B B/F BOILER |
41-315-50 |
|
| 52 SUPER BOILER |
41-315-47 |
|
| 52B SUPER (UWS) BOILER |
41-315-48 |
|
| 65-80 CAT IN CF BOILER |
41-315-57 |
|
| 65-80 CAT 2TN CF BOILER |
41-315-51 |
|
| 65-80B BALANCED FLUE CAT IN BOILER |
41-315-58 |
|
| 65-80B BALANCED FLUE CAT 2TN BOILER |
41-315-52 |
|
| 67/75 B,SB AND GW 75B |
41-315-21 |
|
| 67/75 CF/SB AND GW 75 BOILER |
41-315-20 |
|
| 85-100 CAT IN CF BOILER |
41-315-59 |
|
| 85-100 CAT 2TN BOILER |
41-315-53 |
|
| 85-100B B/F NG BOILER |
41-315-60 |
|
| 85-100B BF |
41-315-54 |
|
| 92/100 B SB AND GW 100B |
41-315-23 |
|
| 92/100 CF/SB AND GW 100 BOILER |
41-315-22 |
|
| FUELSAVER 12CF |
41-047-05 |
|
| FUELSAVER 12RS |
41-047-04 |
|
| FUELSAVER 15CF |
41-047-03 |
|
| FUELSAVER 15CF 2 |
41-047-09 |
|
| FUELSAVER 15RS |
41-047-02 |
|
| FUELSAVER 15RS 2 |
41-047-08 |
|
| FUELSAVER 18RS |
41-047-12 |
|
| FUELSAVER 20RS |
41-047-06 |
|
| FUELSAVER 25-30 |
41-315-80 |
|
| FUELSAVER 25-30B |
41-315-79 |
|
| FUELSAVER 30-40 |
41-315-82 |
|
| FUELSAVER 30-40B |
41-315-81 |
|
| FUELSAVER 40-50 |
41-315-84 |
|
| FUELSAVER 40-50B |
41-315-83 |
|
| FUELSAVER 55-60B |
41-315-85 |
|
| FUELSAVER 60-70B |
41-315-87 |
|
| FUELSAVER 9CF |
41-047-11 |
|
| FUELSAVER 9RS |
41-047-10 |
|
| SUNROD 125 BSB ALL GAS BOILER |
41-314-85 |
|
| SUNROD G 100 ALL GAS BOILER |
41-314-78 |
|
| SUNROD G 100 B |
41-314-41 |
|
| SUNROD G 100 B ALL GAS BOILER |
41-314-80 |
|
| SUNROD G 100 BASIC |
41-314-39 |
|
| SUNROD G 100 BSB |
41-314-42 |
|
| SUNROD G 100 BSB ALL GAS BOILER |
41-314-81 |
|
| SUNROD G 100 SB |
41-314-40 |
|
| SUNROD G 100 SB ALL GAS BOILER |
41-314-79 |
|
| SUNROD G 125 B ALL GAS BOILER |
41-314-84 |
|
| SUNROD G 125 B STANDARD BOILER |
41-314-20 |
|
| SUNROD G 125 BSB STANDARD BOILER |
41-314-22 |
|
| SUNROD G 125 C/F ALL GAS BOILER |
41-314-82 |
|
| SUNROD G 125 SB ALL GAS BOILER |
41-314-83 |
|
| SUNROD G 125 SB STANDARD BOILER |
41-314-21 |
|
| SUNROD G125 STANDARD BOILER |
41-314-19 |
|
| SUNROD G125B MK 2 BOILER |
41-315-30 |
|
| SUNROD G5 BOILER |
41-314-08 |
|
| SUNROD G50 ALL GAS BOILER |
41-314-24 |
|
| SUNROD G50 B2 BOILER |
41-314-14 |
|
| SUNROD G50 BF BOILER |
41-314-32 |
|
| SUNROD G50 BSB ALL GAS BOILER |
41-314-27 |
|
| SUNROD G50 HONEYWELL CONTROL |
41-314-88 |
|
| SUNROD G50 NON ELECT (SPERRYN 880) |
41-314-86 |
|
| SUNROD G50 SB ALL GAS BOILER |
41-314-26 |
|
| SUNROD G50 SB |
41-314-10 |
|
| SUNROD G50 SPERRYN CONTROL 805 |
41-314-87 |
|
| SUNROD G50 W/- (SPERRYN G840) CF |
41-315-24 |
|
| SUNROD G50/2 BSB |
41-314-33 |
|
| SUNROD G50/2 BSB AG |
41-314-31 |
|
| SUNROD G50/2 HONEYWELL CONTROL |
41-314-89 |
|
| SUNROD G50/2 SPERRYN CONTROL 880 |
41-314-90 |
|
| SUNROD G50/2AG |
41-314-28 |
|
| SUNROD G50/2SB |
41-314-12 |
|
| SUNROD G50/2SB AG |
41-314-30 |
|
| SUNROD G50/B2 AG |
41-314-29 |
|
| SUNROD G50B |
41-314-13 |
|
| SUNROD G50B ALL GAS BOILER |
41-314-25 |
|
| SUNROD G75 ALL GAS BOILER |
41-314-74 |
|
| SUNROD G75 BSB ALL GAS BOILER |
41-314-77 |
|
| SUNROD G75 SB ALL GAS BOILER |
41-314-75 |
|
| SUNROD G75 SB |
41-315-09 |
|
| SUNROD G75 SB |
41-315-08 |
|
| SUNROD G75 STD |
41-315-07 |
|
| SUNROD G75 STD |
41-315-06 |
|
| SUNROD G75B ALL GAS |
41-314-76 |
|
| SUNROD G75B B/F |
41-315-10 |
|
| SUNROD G75B BF |
41-315-11 |
|
| SUNROD G75B SB BF |
41-315-13 |
|
| SUNROD G75B SB BF |
41-315-12 |
|
| THERMGLOW 1 |
41-314-01 |
|
| THERMGLOW 2 CF |
41-314-48 |
|
| THERMGLOW 2 CF |
41-314-47 |
|
| THERMGLOW 2 SB |
41-314-52 |
|
| THERMGLOW 2 SB |
41-314-51 |
|
| THERMGLOW 2B |
41-314-54 |
|
| THERMGLOW 2B |
41-314-56 |
|
| THERMGLOW 2S |
41-314-49 |
|
| THERMGLOW 3 ALL GAS |
41-314-68 |
|
| THERMGLOW 3 ALL GAS |
41-314-67 |
|
| THERMGLOW 3 B ALL GAS |
41-314-71 |
|
| THERMGLOW 3 B |
41-314-62 |
|
| THERMGLOW 3 |
41-314-57 |
|
| THERMGLOW 3 BSB ALL GAS |
41-314-72 |
|
| THERMGLOW 3 BSB |
41-314-64 |
|
| THERMGLOW 3 S ALL GAS |
41-314-73 |
|
| THERMGLOW 3 S |
41-314-65 |
|
| THERMGLOW 3 SB ALL GAS |
41-314-69 |
|
| THERMGLOW 3 SB ALL GAS |
41-314-70 |
|
| THERMGLOW 3 SB |
41-314-60 |
|
| THERMGLOW 3 SB |
41-314-59 |
|
| THERMGLOW 3 |
41-314-58 |
|
GLYNWED LTD (2 models)
| Model |
GC Number |
Components |
| AGA 35-40 GAS AIR HEATER |
42-023-01 |
G, I |
| AGA – GAS AIR G35-40B |
42-023-02 |
G, I |
JOHNSON & STARLEY LTD (76 models)
| Model |
GC Number |
Comments |
Components |
| J54-64 MAF VI |
42-416-28 |
|
T |
| CG 50/60 HB (CG 55) AIR HEATER |
42-416-47 |
WCM* |
R, I |
| JWD 32/45V MK2 CF AIR HEATER |
42-416-60 |
WCM* |
R |
| J25-32 AIR HEATER |
42-416-65 |
WCM* |
R, I |
| J25-32R AIR HEATER |
42-416-66 |
WCM* |
R, I |
| J54/64 AIR HEATER |
42-416-70 |
WCM* |
T |
| JWD 38/50 AIR HEATER |
42-416-77 |
WCM* |
R, I |
| J25-32 MAF |
42-416-79 |
WCM* |
R, I |
| J25-32R MAF |
42-416-80 |
WCM* |
R, I |
| JWD 38/50/MAF |
42-416-81 |
WCM* |
R, I |
| J54-64MAF |
42-416-82 |
WCM* |
T |
| J25-32 MK2 AIR HEATER |
42-416-84 |
WCM* |
R, I |
| J25-32R MK2 |
42-416-85 |
WCM* |
R, I |
| J25-32 MK2/MAF |
42-416-88 |
WCM* |
R, I |
| J25-32R MK2/MAF |
42-416-89 |
WCM* |
R, I |
| J15-22 |
42-417-01 |
|
R, I |
| J15-22R |
42-417-02 |
|
R, I |
| J15-22 MAF |
42-417-03 |
|
R, I |
| J15-22R1MAF |
42-417-04 |
|
R, I |
| J25-32 MK3 AIR HEATER |
42-417-11 |
|
R, I |
| J25-32R MK3 |
42-417-12 |
|
R, I |
| J25-32 MK3/MAF |
42-417-13 |
|
R, I |
| J25-32R MK3/MAF |
42-417-14 |
|
R, I |
| J25-32 MK3/MAF VI |
42-417-24 |
|
R, I |
| J25-32R MK3/MAF VI |
42-417-25 |
|
R, I |
| JWD 38/50/MAF VI |
42-417-27 |
|
R, I |
| JWD 32/45V MK2 CF AIR/WH |
43-416-04 |
|
T |
| J25-32/JAN AIR/WH |
43-416-07 |
|
R, I |
| J25-32R/JAN AIR/WH |
43-416-08 |
|
R, I |
| J54-64 AIR/WH |
43-416-11 |
|
R, I |
| JWD 38/50/JAN |
43-416-12 |
|
R, I |
| J25-32 MAF/JAN AIR/WH |
43-416-13 |
|
T |
| J25-32R MAF/JAN AIR/WH |
43-416-14 |
|
R, I |
| JWD 38/50/MAF/JAN |
43-416-15 |
|
R, I |
| J54-64 MAF/JAN |
43-416-16 |
|
R, I |
| J25-32 MK2/JAN AIRIWH |
43-416-19 |
|
R, I |
| J25-32R MK2/JAN AIR/WH |
43-416-20 |
|
R, I |
| J25-32 MK2/MAF/JAN AIR/WH |
43-416-21 |
|
R, I |
| J25-32R MK2/MAF/JAN AIR/WH |
43-416-22 |
|
R, I |
| J15-22 JAN |
43-416-23 |
|
R, I |
| J15-22R/JAN |
43-416-24 |
|
R, I |
| J15-22 MAF/JAN |
43-416-25 |
|
R, I |
| J15-22R/MAF/JAN |
43-416-26 |
|
R, I |
| J25-32 MK3/JAN |
43-416-31 |
|
R, I |
| J25-32R MK3/JAN |
43-416-32 |
|
R, I |
| J25-32 MK3/MAF/JAN |
43-416-33 |
|
R, I |
| J25-32R MK3/MAF/JAN |
43-416-34 |
|
R, I |
| J25-32 MK3/MAF V1/JAN |
43-416-43 |
|
R, I |
| J25-32R MK3/MAF V1/JAN |
43-416-44 |
|
R, I |
| JWD 38/50/MAF V1/JAN |
43-416-46 |
|
R, I |
| J54-64 MAFV1/JAN |
43-416-47 |
|
T |
| JWD 32-45 X |
43-416-01 |
|
R, I |
| J25-32 & J25-32R REVERTED CAT 1 |
42-416-68 |
WCM* |
R, I |
| J54-64/MAF V1 |
42-417-28 |
WCM* |
T |
| J54-64 MK2/MAF |
42-417-69 |
WCM* |
T |
| J25-32 MK3/SUPERJAN J25-32 |
42-417-80 |
WCM* |
R, I |
| J25-32 MK3/MAF/SUPERJAN |
42-417-81 |
WCM* |
R, I |
| J25-32 MK3/MAF V1/SUPERJAN |
42-417-82 |
WCM* |
R, I |
| J25-32R MK3/SUPERJAN |
42-417-83 |
WCM* |
R, I |
| J25-32R MK3/MAF/SUPERJAN |
42-417-84 |
WCM* |
R, I |
| J25-32R MK3/MAF V1/SUPERJAN |
42-417-85 |
WCM* |
R, I |
| J25-32/JAN & 125-32 R/JAN REVERTED CAT 1 |
43-416-09 |
WCM* |
R, I |
| J25-32 Mk3/ELJ |
43-416-75 |
|
R, I |
| J25-32 Mk3/MAF/ELJ |
43-416-76 |
|
R, I |
| J25-32 Mk3/MAFV1/ELJ |
43-416-77 |
|
R, I |
| J25-32R Mk3/ELJ |
43-416-78 |
|
R, I |
| J25-32R Mk3/MAF/ELJ |
43-416-79 |
|
R, I |
| J25-32R Mk3/MAFV1/ELJ |
43-416-80 |
|
R, I |
| J25-32 Mk3/HIJ |
43-416-90 |
|
R, I |
| J25/32 Mk3/MAF/HIJ |
43-416-91 |
|
R, I |
| J25-32 Mk3/MAFV1/HIJ |
43-416-92 |
|
R, I |
| J25-32R Mk3/HIJ |
43-416-93 |
|
R, I |
| J25-32R Mk3/MAF/HIJ |
43-416-94 |
|
R, I |
| J25-32R Mk3/MAFV1/HIJ |
43-416-95 |
|
R, I |
| J54-64 Mk2/ELJ |
43-417-53 |
|
T |
| J54-64 Mk2/MAF/ELJ |
43-417-54 |
|
T |
POTTERTON MYSON LTD (58 models)
| Model |
GC Number |
Comments |
Components |
| WARMAIR 20/25 AIR HEATER |
42-590-01 |
|
G |
| WARMAIR 25/30 |
42-590-02 |
|
G |
| WARMAIR28 SD |
42-590-03 |
|
G |
| WARMAIR 40/50 AIR HEATER |
42-590-05 |
|
G |
| WARMAIR 50/60 |
42-590-06 |
|
G |
| WARMAIR 20/25 STOREY HEIGHT WAU |
42-590-07 |
|
G |
| WARMAIR 25/30 STOREY HEIGHT WAU |
42-590-08 |
|
G |
| WARMAIR 20/25B, SHB, SHRB, SHBW & SHRBW |
42-590-09 |
|
G |
| WARMAIR 25/30B SHB,SHRB,SHBW,SHRBW |
42-590-09 |
|
G |
| WARMAIR 28SD SH MK3 AIR HEATER |
42-590-13 |
|
G |
| WARMAIR 22/30 BASIC & SH AIR HEATERS |
42-590-14 |
|
I |
| WARMAIR 22/30 SHW WITH ASCOT 303 WE/2 WH |
42-590-14 |
|
I |
| WARMAIR 22/30 SHR STOREY HEIGHT AIR/WH |
42-590-15 |
|
I |
| WARMAIR 22/30 SHRW WITH ASCOT 303 WE/2 WH |
42-590-15 |
|
I |
| WARM-AIR 28 SD MTE AFTER 1/4/68 |
42-590-10 |
|
G |
| FLAMINGO 50BF WM |
41-601-14 |
|
G, I |
| FLAMINGO CF20-30 |
41-601-33 |
|
G, I |
| FLAMINGO CF50 |
41-601-18 |
|
G, I |
| FLAMINGO RS 13 |
41-601-06 |
|
G, I |
| FLAMINGO RS 13 |
41-601-12 |
|
G, I |
| FLAMINGO RS20-30 |
41-601-23 |
|
G, I |
| FLAMINGO RS40 |
41-601-25 |
|
G, I |
| FLAMINGO RS50S |
41-601-43 |
|
G, I |
| KINGFISHER 180 & 220 |
41-601-19 |
|
G, I |
| KINGFISHER 180 & 220 |
41-601-20 |
|
G, I |
| KINGFISHER 180CF |
41-605-80 |
To Ser No GTW 16482 |
G, I |
| KINGFISHER 220CF |
41-605-81 |
To Ser No GSV 16482 |
G, I |
| KINGFISHER CF 100 |
41-601-42 |
|
G, I |
| KINGFISHER CF 125 |
41-601-15 |
|
G, I |
| KINGFISHER CF 150 |
41-601-16 |
|
G, I |
| KINGFISHER CF40 |
41-601-57 |
To Ser No GTD 26763 |
G, I |
| KINGFISHER CF40A |
41-601-60 |
To Ser No GTF 07186 |
G, I |
| KINGFISHER CF45 |
41-601-07 |
|
G, I |
| KINGFISHER CF50 |
41-601-58 |
To Ser No GTW 29752 |
G, I |
| KINGFISHER CF50A |
41-601-61 |
To Ser No GSY 02260 |
G, I |
| KINGFISHER CF55 |
41-601-08 |
|
G, I |
| KINGFISHER CF60 |
41-601-56 |
To Ser No GSZ 02050 |
G, I |
| KINGFISHER CF60 |
41-601-38 |
|
G, I |
| KINGFISHER CF80 |
41-601-39 |
|
G, I |
| KINGFISHER CF90 |
41-601-40 |
|
G, I |
| KINGFISHER RS 100 |
41-601-59 |
To Ser No GTT 09197 |
G, I |
| KINGFISHER RS50 |
41-601-48 |
|
G, I |
| KINGFISHER RS50 |
41-601-49 |
|
G, I |
| KINGFISHER RS60 |
41-601-37 |
|
G, I |
| KINGFISHER RS80 |
41-601-41 |
|
G, I |
| NETAHEAT ELECTRONIC 10/16 |
41-601-67 |
To Ser No GQY 04342 |
G, I |
| NETAHEAT ELECTRONIC 16/22 |
41-601-66 |
To Ser No GQZ 04834 |
G, I |
| NETAHEAT ELECTRONIC 6/10 |
41-601-68 |
To Ser No GUA 07847 |
G, I |
| NETAHEAT MKI BF 10/16 |
41-601-03 |
To Ser No GUA 07847 |
G, I |
| NETAHEAT MKI BF 16/22 |
41-601-04 |
To Ser No GUB 18601 |
G, I |
| NETAHEAT MK2 10/16 |
41-601-10 |
To Ser No GUB 18601 |
G, I |
| NETAHEAT MK2 16/22 |
41-601-11 |
To Ser No GUC 16845 |
G, I |
| NETAHEAT Mk2e 10/16 – FIELD TRIAL |
41-601-62 |
To Ser No GUC 16845 |
G, I |
| NETAHEAT MK2e 16/22 (FIELD TRIAL) |
41-601-63 |
To Ser No GSC 15445 |
G, I |
| NETAHEAT MK2F 10/16 |
41-601-34 |
To Ser No GTU 06996 |
G, I |
| NETAHEAT MK2F 10/16 – PCB From Ser No PCA |
41-601-34 |
To Ser No GTL 39870 |
G, I |
| NETAHEAT MK2F 16/22 |
41-601-35 |
To Ser No 70216 |
G, I |
| NETAHEAT MK2F 16/22 – PCB From Ser No PCB |
41-601-35 |
To Ser No 155008 / To Ser No 20046 |
G, I |
SPEEDAIRE LTD (LINCOLN) (13 models)
| Model |
GC Number |
Components |
| LGCS 48 LX AIR HEATER |
42-452-05 |
CI |
| LGCS 72 LX |
42-452-11 |
CI |
| LGC 85 LX WARM AIR HEATER |
42-452-14 |
CI |
| LGC 115 LX AIR HEATER |
42-452-20 |
CI |
| LGH 115 LX |
42-452-21 |
CI |
| LGL 115 LX |
42-452-22 |
CI |
| LGC 130 LX |
42-452-23 |
CI |
| LGH 130 LX |
42-452-24 |
CI |
| LGL 130 LX |
42-452-25 |
CI |
| LGC 115E |
42-454-29 |
CI |
| LNC 45 |
43-452-17 |
GI |
| LNC 60 |
43-452-18 |
GI |
| LGC/S 48, 60, 72 LX |
42-452-08 |
CI |
SUTHERLAND (4 models)
| Model |
GC Number |
Components |
| AGS 302/SH2 |
42-778-27 |
I |
| AGS 302/SF2 |
42-778-27 |
I |
| AGS 302/2 AIR HEATER |
42-778-31 |
I |
| AGS 302/2 AIR AND WATER HEATER |
43-778-15 |
I |
THORN HEATING (86 models)
| Model |
GC Number |
Components |
| HALCYON F60 C/F AIR HEATER |
42-766-06 |
G |
| HALCYON FH60 AIR HEATER |
42-766-08 |
G |
| HALCYON FCH 60 |
42-766-09 |
G |
| 25/30 TN CF AIR HEATER |
42-766-42 |
G |
| 25/30 TN (R) CON FLUE |
42-766-43 |
G |
| 25/30 TN BF |
42-766-44 |
G |
| 25/30 TN (R) BAL FLUE |
42-766-45 |
G |
| 25/30 TN SD |
42-766-46 |
G |
| 25/30 TN (R) SE DUCT |
42-766-47 |
G |
| HALCYON 22TN CF |
42-766-54 |
G |
| HALCYON 22TN (R) CF |
42-766-57 |
G |
| HALCYON 2 CF, BF, SD AIR HEATER |
42-789-01 |
G |
| 30/40A |
42-789-11 |
G |
| 30/40A SH |
42-789-12 |
G |
| 30/40A SF |
42-789-13 |
G |
| THORN 30/40 AH WITH CONTROLAlRE |
42-789-23 |
G |
| THORN 30/40 AH WITH CONTROLAIRE |
42-789-24 |
G |
| HALCYON 22/WH BF AIR/WH |
43-766-02 |
G |
| HALCYON 22/WH SD AIR/WH |
43-766-03 |
G |
| HALCYON F60/WH CF AIR/AH |
43-766-04 |
G |
| HALCYON F60/WH SD AIR/WH |
43-766-05 |
G |
| HALCYON F60/WH BF AIR/WH |
43-766-14 |
G |
| HALCYON 22 WH/TN CF/ASCOT 303 WE/1 |
43-766-15 |
G |
| HALCYON 22 WH/TN BF/ASCOT 303 WE/1 |
43-766-16 |
G |
| HALCYON 22 WH/TN SE/ASCOT 303 WE/1 |
43-766-17 |
G |
| HALCYON 22 WH/TN (R) CF/ASCOT 303 WE/1 |
43-766-18 |
G |
| HALCYON 22 WH TN (R) BF/ASCOT 303 WE/1 |
43-766-19 |
G |
| HALCYON 22 WH TN (R) SD/ASCOT 303 WE/1 |
43-766-20 |
G |
| HALCYON 25/30/WH/TN CF/ASCOT 303 WE/1 |
43-766-31 |
G |
| HALYCON 25/30/WH/TN/(R) CF/ASCOT 303 WE/1 |
43-766-32 |
G |
| HALCYON 22 WHTN / ISIS WH |
43-766-38 |
G |
| HALCYON 22 WHTN(R) CF/ ISIS CIRCULATOR |
43-766-39 |
G |
| HALCYON 25/30 WHITN W/ISIS WH |
43-766-45 |
G |
| HALCYON 25/30 WHTN W/ISIS WH |
43-766-46 |
G |
| SUGG 25/30MW WITH THORN W WH |
43-766-51 |
G |
| HALCYON 2 CF, BF, SD WITH MINERVA WAE/A |
43-789-01 |
G |
| 30/40W |
43-789-08 |
G |
| 30/40 SHW |
43-789-09 |
G |
| 30/40 SFW |
43-789-10 |
G |
| 30/40WH |
43-789-18 |
G |
| 30/40WH AIR/WATER HEATER |
43-789-19 |
G |
| HALCYON 17(R) AIR HEATER |
42-766-02 |
G |
| HALCYON TYPE 35 |
42-766-03 |
G |
| HALCYON 35R |
42-766-04 |
G |
| HALCYON F120 CONVENTIONAL |
42-766-10 |
G |
| HALCYON TYPE 35 DUAL |
42-766-18 |
G |
| HALCYON FH60 BF |
42-766-34 |
G |
| HALCYON FH60 SD |
42-766-35 |
G |
| HALCYON FCH60 BF |
42-766-36 |
G |
| HALCYON FCH60 SD |
42-766-37 |
G |
| HALCYON F120 BF |
42-766-40 |
G |
| HALCYON F120 SD |
42-766-41 |
G |
| HALCYON F60 BF |
42-766-52 |
G |
| HALCYON F60 SD |
42-766-53 |
G |
| HALCYON 22TN BF |
42-766-55 |
G |
| HALCYON 22TN SD |
42-766-56 |
G |
| HALCYON 22TN (R) BF |
42-766-58 |
G |
| HALCYON 22TN (R) SD |
42-766-59 |
G |
| 40/50 TN (R) CF |
42-766-65 |
G |
| SLIMWALL 30 AIR & AIR/WATER HTR SERIES |
42-766-67 |
G |
| SLIMWALL 30 TN (R) CF |
42-766-68 |
G |
| SLIMWALL 30 TN RD CF WITH RISING DUCT |
42-766-74 |
G |
| SLIMWALL 30 TN RD CF R.C. RISING DUCT |
42-766-75 |
G |
| SLIMWALL 30TN SD WARM AIR HEATER |
42-766-76 |
G |
| SLIMWALL 30 TN SD(R) |
42-766-77 |
G |
| HALCYON 40/60 AIR HEATER |
42-766-82 |
G |
| HALCYON 60/80 AIR HEATER |
42-766-83 |
G |
| SUGG 25/30M AIR HEATER |
42-766-88 |
G |
| 30/40A AIR HEATER FITTED CONTROLAIRE |
42-789-18 |
G |
| HALCYON TYPE 22 WH CONV |
43-766-01 |
G |
| HALCYON F120 WH COMBINED AIR/WH |
43-766-06 |
G |
| HALCYON F120 WH BALANCED FLUE |
43-766-07 |
G |
| HALCYON F120 WH SEDUCT |
43-766-08 |
G |
| HALCYON 17WH(R) AIR/WATER HEATER |
43-766-10 |
G |
| HALCYON TYPE 22 WH CONVENTIONAL (R) |
43-766-11 |
G |
| HALCYON TYPE 22 WH BALANCED FLUE (R) |
43-766-12 |
G |
| HALCYON TYPE 22 WH SEDUCT |
43-766-13 |
G |
| SLIMWALL 30 WH TN CF / ASCOT WE/1 |
43-766-27 |
G |
| SLIMWALL 30 WH TN WITH ASCOT 303WE/1 |
43-766-28 |
G |
| SLIMWALL 30 WH TN RD WITH ASCOT 303WE/1 |
43-766-29 |
G |
| SLIMWALL 30 WH TN RD(R) WITH ASCOT 303 WE/1 |
43-766-30 |
G |
| HALCYON 40/60 WH AIRIW/H (MADE BY GSW) |
43-766-40 |
G |
| SUGG 25/30M WITH ISIS CIRCULATOR WAE/C |
43-766-44 |
G |
| SUGG 25/30M WITH MINERVA WAE/C |
43-766-47 |
G |
| SUGG 25/30M WITH MAXOL TH 30/D |
43-766-50 |
G |
| 30/40W AIR/WATER HEATER WITH CONTROLAIRE |
43-789-15 |
G |
VAILLANT (8 models)
| Model |
GC Number |
Comments |
Components |
| COMBICOMPACT VCW 242E |
47-044-13 |
Pre 1991 |
|
| COMBICOMPACT VCW 282E |
47-044-18 |
Pre 1991 |
|
| T3W VCW SINE 18 |
47-044-01 |
Pre 1991 |
|
| T3W VCW SINE 20/1 |
47-044-03 |
Pre 1991 |
|
| T3W VCW SINE 25/1 |
47-044-05 |
Pre 1991 |
|
| COMBICOMPACT VCW 221 |
47-044-14 |
|
SW |
| COMBICOMPACT VCW 240 |
47-044-15 |
|
SW |
| COMBICOMPACT VCW 280 |
47-044-16 |
|
SW |
Source: Gas Safe Register Technical Bulletin 070, issued 7 June 2012, compiled in association with HSE Information Document OC No. 265/49 (Rev 1). Provided for general reference only.
Can’t find your appliance, or not sure what the list means?
Tell us the make and model and we’ll talk you through your options. A photo of the data plate helps, as long as you can take it without opening or moving the appliance.
📞 07703 203930 📞 07711 855891
How HSG Surveys Can Help
We work with homeowners, landlords, letting agents, businesses and contractors who’ve found an old appliance and need a clear answer before they go any further.
Asbestos Management Surveys
If you’re responsible for a workplace or the common parts of a multi-occupied building, a management survey shows where asbestos could be disturbed during normal use and routine maintenance. It can include older appliances containing asbestos, and it gives you a written record to work from. Read our full guide to how these surveys work.
Asbestos Refurbishment & Demolition Surveys
Replacing a heating system or refitting a kitchen in a pre-2000 building can disturb far more than the appliance itself. A refurbishment and demolition survey checks the areas being worked on, so appliances containing asbestos and hidden materials nearby can be dealt with before contractors start. See our detailed breakdown of this survey type.
Asbestos Sampling & Testing
Sometimes you only need an answer about one material. Where it can be reached safely, we can take a bulk sample from suspected appliances containing asbestos and send it to a UKAS-accredited laboratory, with results typically back within a few working days. Find out more about sampling and testing.
Areas We Cover
We’re based in West Yorkshire and carry out inspections, sampling and surveys across the North of England. Take a look at our West Yorkshire coverage page, or call us and we’ll confirm coverage for your area.
Appliances Containing Asbestos – Frequently Asked Questions
Does my old appliance contain asbestos?
You can’t tell by looking at it. Note the make, model and any serial or GC number from the data plate, then check them against our reference list. If you can’t find a clear match, leave the appliance alone and call us for advice.
What if my appliance isn’t on the list?
That doesn’t prove it’s asbestos free. The list isn’t exhaustive, so treat an older appliance with caution until you have a clear answer, especially if it’s damaged or due to be moved.
If my model is listed as asbestos free, is it definitely safe to work on?
It’s a good sign, but check the exact model, serial number and production date, because some entries depend on all three. Parts may also have been replaced over the years, so take specialist advice if there’s any doubt.
Do I have to remove a heater that contains asbestos?
Not usually. A heater in good condition can often stay where it is, as long as it isn’t damaged or disturbed. Removal becomes important when it’s deteriorating or when refurbishment work will affect it, and that job shouldn’t be done as DIY.
Can you test appliances containing asbestos?
Yes, where the material can be reached safely. We can inspect the appliance, take a sample if it’s suitable and send it to a UKAS-accredited laboratory for analysis. Please don’t open the casing or take your own sample first.
How do I get rid of appliances containing asbestos?
Don’t put them in a household bin or a general waste skip. Appliances containing asbestos need to be removed and disposed of as asbestos waste, so call us before you disconnect or move one. We’ll explain the safest route for your property.
Should landlords check for appliances containing asbestos?
Yes, particularly before maintenance, a heating upgrade or a change of tenant. Knowing whether a property has appliances containing asbestos helps you warn contractors and plan work safely. The duty to manage asbestos also applies to the common parts of multi-occupied buildings.